DVP DC.16DEX Скачать руководство пользователя страница 8

 

 

Operating and Maintenance Instructions

 

EN 

DC.16DEX

 

 

 

www.dvp.it 

8702042 – 01/10/2014 – R.4 

 

 

PUMP DESCRIPTION 

 

3.1 

INTENTED USE AND CONTRAINDICATIONS 

 

3.1.1 

INTENTED USE 

The  pumps  described  in  this  manual  are  of  the  rotary  vane  oil  bath  type.  These  pumps  are  specifically 
designed  for  ATEX  Zone  2  suction  from  clean  air,  flammable  gas  from 

IIA

IIB

  and 

IIC

  units  or  small 

amounts of water vapours and must be installed in NON ATEX classified environments; their marking and 
certification and for internal ATEX (see 1.7 "Marking" of this manual). 
The temperature of the fluid, gas or vapour produced by the pump and that from the environment in which 
it is installed must be b12°C and +40°C. 

 

 

 

HAZARD 
The user must pay particular attention to the Marking of the pump. 

 

Any  other  use  is  prohibited.  The  Manufacturer  is  not  liable  for  any  damage  to  persons  and/or  property  caused  by 
improper use or not allowed use of the pump. 
This pump is suitable for emptying closed containers with a capacity that the pump can reach the final pressure in 
less than 20 minutes. 
 

3.1.2 

CONTRAINDICATIONS 

 

 

 

The pump cannot work with the intake completely open for more than 10 minutes. 

 

 

 

 

 

Any  use  other  than  that  for  which  the  pump  was  constructed  is  to  be  considered  an 
abnormal  condition  and  therefore  can  cause  damage  to  the  pump  and  pose  a  serious 
danger to the operator. 

 

Below  is  a  series  of  operations  involving  improper  use  of  the  pump,  which  are  not  permitted  under  any 
circumstances. 

  Do  not  install  and/or  use  the  pump  in  an  ATEX  classified  environment;  The  pump  is  certified  and  marked  for 

internal ATEX

 (see 1.7 "Marking" of this manual). The use of the pump in an environment where the presence 

of ATEX atmospheres has been detected can cause explosions or fires;

 

  Do not use non-original spare parts or parts not provided by the manufacturer. 

  Do  not  use  the  unit  to  pump  solid  materials,  chemicals,  powders,  solvents  or  other  substances  differing  from 

those permitted These types of materials may damage the unit, degrade its performance or reduce its life. 

  do not expose the pump to rain, steam or excessive humidity. 

  Do not place or store near in the proximity of flammable or combustible materials or substances. 

  Do not use the pump as a compressor. 

 

3.2 

NOISE EMISSION 

This pump has been designed and constructed to reduce noise at its source. 
The  sound  pressure  levels  contained  in  the  table  of  technical specifications were measured at maximum vacuum 
and outlet conveyed according to UNI EN 2151. 

Содержание DC.16DEX

Страница 1: ...VACUUM TECHNOLOGY OPERATING AND MAINT ENANCE INSTRUCTIONS Translation of the original instructions OIL BATH VANE VACUUM PUMPS DC 16DEX www dvp it info dvp it...

Страница 2: ...g its clientele to reach its objectives For this reason our customers are the focus of our attention and we promote the sending of suggestions and or proposals for improvements that could be applied t...

Страница 3: ...ISTICS 7 4 INSTALLATION 8 4 1 RECEIPT AND CONTENT VERIFICATION 8 4 2 PACKAGING 8 4 3 TRANSPORT AND HANDLING 8 4 4 STORAGE 8 4 5 ENVIRONMENTAL CONDITIONS 9 4 6 PUMP INSTALLATION 9 4 7 MOTOR INSTALLATIO...

Страница 4: ...cations regarding the pump pump model and serial number year of manufacture date of purchase detail information regarding problems verified 1 3 METHOD OF CONSULTATION For improved understanding of the...

Страница 5: ...Equipment unit I underground II surface 3 Category of the equipment pump in category 3 internal NOT ATEX certified for the external surface Category 3 comprises equipment designed to operate in accord...

Страница 6: ...a protected area that is accessible only by authorised personnel and only perform operations when the pump is stopped and cooled Hazard generated by low pressure Avoid contact with pump intake attach...

Страница 7: ...jection hazard Install the pump in order to avoid those in charge of works being directly hit by parts or bits of parts flying through the fan cover casing due to the cooling fan breaking 2 3 PICTOGRA...

Страница 8: ...more than 10 minutes Any use other than that for which the pump was constructed is to be considered an abnormal condition and therefore can cause damage to the pump and pose a serious danger to the o...

Страница 9: ...tial final pressure Abs Mc Leod mbar micron 0 0005 0 37 Final pressure with gas ballast Abs mbar hPa 0 08 Max inlet pressure for water vapour mbar hPa 17 23 Max water vapour pumping rate Kg h 0 22 0 3...

Страница 10: ...qualified and experienced personnel The pump can be raised and moved only with forklift trucks or with lifting equipment ropes hooks etc applied to the pump as shown in the figure and adjusted to the...

Страница 11: ...on Temperature Humidity and altitude The corresponding limit values are shown in the table of the technical specifications see 3 3 Dimensions and characteristics of this manual Please contact the Manu...

Страница 12: ...exceeded or a degradation in the level of protection of the pump itself HAZARD The user must ensure that the temperature of the flammable liquid gas or vapour produced by the pump is higher than the...

Страница 13: ...ues contained on the motor rating plate The connection cable must be adequate for the power absorbed by the pump absorption values are shown on the pump motor rating plate taking into account the envi...

Страница 14: ...due to the opening of the oil filler cap WARNING When filling the oil tank never exceed allowed maximum level Undo the oil filler plug Pour oil in the tank up to mid range of the oil sight glass Clos...

Страница 15: ...ast valve no 5 of 2 turns Let pump run under these conditions for at least 1 hour If oil appearance is not back to normal light colour and no signs of emulsifying change oil 5 1 4 STOP The pump must b...

Страница 16: ...ner inconsistent with instructions with non original spare parts or otherwise so as to impair its integrity or modify its characteristics D V P Vacuum Technology s p a will be released from any liabil...

Страница 17: ...al of used or polluted oil 6 2 3 CHECK AND CLEAN GAS BALLAST HAZARD Before carrying out the operations listed below isolate the pump from the operating system by means of an isolation valve required i...

Страница 18: ...as well as the spare part purchase number DESCRIPTION DC 16DEX Kit minor K9602028 Kit major K9602028 1 Olio 1 dm 8833100 SW100 Olio 5 dm 8833500 SW100 Gas ballast gasket 1001018 D V P Vacuum Technolog...

Страница 19: ...2042 01 10 2014 R 4 www dvp it 7 HOW TO RETURN THE PUMP The product may only be returned after prior agreement with the supplier who will provide the authorisation number that must accompany the mater...

Страница 20: ...it Demolition of the pump must be performed by authorised technicians Metal parts can be disposed of as scrap metal All materials deriving from demolition must be disposed of according to regulations...

Страница 21: ...lter C Pump is noisy Motor coupling damaged where present Contact Service Department Bearings damaged Contact Service Department Vanes worn out Contact Service Department Wrong motor rotation Check el...

Страница 22: ...Operating and Maintenance Instructions EN DC 16DEX 20 www dvp it 8702042 01 10 2014 R 4...

Страница 23: ...t appear to be faulty due to negligence and or carelessness during use failure to observe the equipment operating instructions lack of maintenance incorrect installation and or maintenance maintenance...

Страница 24: ...Cod 8702042 01 10 2014 R 4 EN D V P Vacuum Technology s p a Via Rubizzano 627 40018 San Pietro in Casale BO Italy Ph 3905118897101 Fx 3905118897170 Email info dvp it...

Отзывы: