EN
Operating and Maintenance Instructions
DC.16DEX
19
8702042 – 01/10/2014 – R.4
www.dvp.it
9
TROUBLESHOOTING
DAMAGE
CAUSE
REMEDY
(A)
The pump does not run
No voltage
Provide power supply
Thermal switch has tripped
Identify reason and activate switch
Room temperature is too low
Restore room temperature to allowed range
Intake of not allowed substances
Contact Service Department
Motor winding damaged
Contact Service Department
(B)
The pump cannot
reach stated final
pressure (Abs.)
Low oil in tank
Top up oil
Oil contaminated
Change oil
Oil is not the suitable type
Change oil
Wrong motor rotation
Check electrical wiring
Gas ballast is open
Close gas ballast
Discharge clogged
Check couplings at outlet
Intake filter clogged (if present)
Clean the filter
(C)
Pump is noisy
Motor coupling damaged
(where present)
Contact Service Department
Bearings damaged
Contact Service Department
Vanes worn out
Contact Service Department
Wrong motor rotation
Check electrical wiring
(D)
Pump runs hot
Oil is not the suitable type
Change oil
Oil contaminated
Change oil
Poor room ventilation
Install an auxiliary ventilator
Motor fan broken
Contact Service Department
Motor fan guard clogged
Clean motor fan guard
Wrong power supply to motor
Check power supply
Discharge clogged
Check couplings at outlet
(E)
High oil consumption
High working pressure
(close to atmospheric pressure)
Check oil level frequently
Pump runs hot
See point “D”
(F)
Pump does not
maintain vacuum after
power-off
Check valve/system damage
Contact Service Department
(G)
Pump leaks oil
Tank screws or plugs loosened
Tighten screws or plugs
Tank gaskets damaged
Contact Service Department
Oil sight glass not tightened
Tighten the oil sight glass