53
/
98
SM-1 Ev4/100901
7.8 Fuses
1
.
5 A – control panel
2
.
20 A – alternator
3
.
20 A – logic, steering servo
4
.
20 A – logic, steering servo
Fuses box
When changing fuses strictly follow the electric current value for which the fuses are designed. Do not replace
damaged fuses with fuses with a higher or lower electric current value. These could cause large damage or even
fire to the mower!
ATTENTION: see section Service Bulletin
8.11 Fuses
7.9 Control panel
-
sig hour meter
1. Power indicator (shines green if power is on)
2. Signal reception (shines green if signal reception is correct)
3. Neutral position (shines green if neutral pos. is correct)
4. Blade (shines red when blade is engaged)
Hour
Hour meter
Control panel
1
+12V
2
ground
3
counter
signal
4
ground
1
2
3
4
1
2
3
4
1.
+12V (red)
2.
ground (blue)
3.
counter signal (brown)
4.
ground (blue)
turn ON
signal
neutral
blade ON