SM-1 Ev4/100901
7
Cut the original pin faston 6,3
Pincers
8
Connect red cable of the main harness with red
cable of the beacon cable and blue cable of the
main harness with blue cable of the beacon cable.
Connect cables by help of connector faston - female
and mount the pin back to the connector cover. (see
the cables orientation)
x
x
Connector pliers
9
Connect the 8pin connector of the indication panel
and mount it back to the original place.
.
10
Connect the beacon connector and new mounted
connector.
Fix the beacon cable to the harness by means the
plastic clippers.
11
Connect the accumulator and a check if the beacon
is working after the machine is ON.
Wrench flat 10