6.26 Exchange of the starter switch relay
-
Disconnect the battery
-
Dismount the relay cables
-
Connect the ground cable under the relay fixing screw during mounting
Check:
-
When the relay switches on, the voltage must be on both heavy-current relay connectors.
-
If not, check the relay control voltage of the supply cable (brown). It should be U = 12V when the relay is
on.
Picture 107
Supply cable
Starter cable
Control cable
Ground