![Dvorak Spider ILD01 Скачать руководство пользователя страница 22](http://html1.mh-extra.com/html/dvorak/spider-ild01/spider-ild01_service-manual_2544107022.webp)
22
/
98
SM-1 Ev4/100901
6.5 Exchange of the hydraulic motor
Dismount:
-
Hydraulic motor hoses
(ATTENTION! The oil must not get on the V-belts!)
-
Expand tank
-
Control unit
-
Dismount the console with control elements from the beam and disconnect the plug of electric motor
-
Dismount the beam and cross (see
6.16 Exchange of the driving belts SPA 1650 LW
)
-
Dismount the pulley and hydraulic motor from the cross (Picture 36)
Picture 36
Picture 37
Mounting: (Take reverse steps)
-
Seal the hydraulic motor and screws with silicone sealing
-
Glue the screw on the pulley shaft (LOCTITE 243)
-
Tight the screws of hydraulic motor pressure hoses to 95 Nm
-
MIND the correct position of sealing rings!
-
After start, slowly increase the driving speed (air in the system – high noise of hydraulic system for about
-
1 minute )
Picture 38
Picture 39
Contact sealing of
hydraulic motor
Hydraulic motor screws
Содержание Spider ILD01
Страница 1: ...SM 1 Ev4 100901 SERVICE MANUAL SPIDER ILD01...
Страница 7: ...7 98 SM 1 Ev4 100901 Ampere meter CEM DT 9701 Voltmeter Ben electronic DT 830 D...
Страница 47: ...47 98 SM 1 Ev4 100901 6 29 Hydraulic diagram Hydraulic oil pressure nominal 90 bar maximal 120 bar...
Страница 82: ...82 98 SM 1 Ev4 100901 Related documents...
Страница 90: ...90 98 SM 1 Ev4 100901...
Страница 91: ...91 98 SM 1 Ev4 100901...
Страница 94: ...94 98 SM 1 Ev4 100901...