30
Instruction Manual AL VOLUMETRIC
ENGLISH
instruction
manual
AL
VOLUMETRIC
16) LED SERVICE AND KNOWLEDGE
Thanks to 4 led lights in different colours and located under
the volumetric “ALIA” valve display (image 9,D), we can un-
derstand what is the step the softener is in.
Each COLOUR stands for a specific function:
• Green
the softener is correctly working
• Red
there is an alarm
• White
stands for the steps that are under way
• Blinking white
indicates date, time and language setting
• Blue
stands for a setting step
CAUTION
: when the softener is in volumetric mode, and water
is being softened, led lights will progressively change from
green to white.
For instance: 1 white led and 3 green led lights mean that the
softener has used 25% of its operating range; while 2 white
leds and 2 green leds mean that its operating range accounts
for 50%.
Consequently, the following coding holds true:
4 BLINKING GREEN LEDs
. . .
OPERATING/SERVICE
4 BLINKING WHITE LEDs ........ LANGUAGE CHOICE
4 BLINKING WHITE LEDs ........ SETTING DATE AND TIME
4 SEQUENTIAL WHITE LEDs .... .RESIN RINSE (B3 for 5 minu-
tes)
4 SEQUENTIAL GREEN LEDs ... *R* (REGENERATION)
1) TIMER SETTINGS
:
1 BLINKING BLUE LED
. . . . .
CHOOSE VOLUMETRIC MODE
YES-NO
1 BLINKING BLUE LED
. . . . .
REGENERATION DAY
1 BLINKING BLUE LED
. . . . .
REGENERATION DAYS
INTERVAL
2 BLINKING BLUE LEDs
. . . . .
REGENERATION TIME
3 BLINKING BLUE LEDs
. . . . .
CHOOSE MODEL 5, 8, 12
3 BLINKING BLUE LEDs
. . . . .
EXTRA-RINSE
4 BLINKING BLUE LEDs
. . . . .
CHOOSE SALT ALARM
4 BLINKING BLUE LEDs
. . . . .
CHOOSE BUZZER
2) INSTALLATION:
2 STEADY WHITE LEDs
. . . . .
B3 COUNTERCURRENT RINSE
4 STEADY WHITE LEDs
. . . . .
B7 1ST REFILL AND RAPID
WASH
3 STEADY WHITE LEDs
. . . . .
B5 SUCKING
4 STEADY WHITE LEDs
. . . . .
B7 2° REFILL AND RAPID
WASH
3) RESIN REGENERATION:
2 STEADY BLUE LEDs
. . . . . .
B3 COUNTERCURRENT RINSE
3 STEADY BLUE LEDs
. . . . . .
B5 SUCKING
4 STEADY BLUE LEDs
. . . . . .
B7 REFILL AND RAPID WASH
4) ALARMS:
4 BLINKING RED LEDs
. . . . .
SALT ALARM TRIGGERED
1 STEADY RED LED
. . . . . . .
ERROR 1
2 STEADY RED LEDs
. . . . . .
ERROR 2
3 STEADY RED LEDs
. . . . . .
REPLACE BATTERY
17) CONNECTION TO EXTERNAL EQUIPMENT
The ALIA valve can send signals to external equipment via the
connections showed in Fig.8, O, M.
Technical connection data are the following:
- connector “O” is based on the MOD BUS RTU protocol (RS
232 external serial connector) (Fig. 8, O).
- connector “M” is used to communicate whether salt is
present in the tank via ON/OFF signals (Fig. 8, M).
Содержание AL 12
Страница 6: ...6 Manuale d istruzione AL VOLUMETRICO FIG 6 FIG 7 TUBO DI SCARICO FIG 5 FIG 4 A FIG 4 B ...
Страница 8: ...8 Manuale d istruzione AL VOLUMETRICO FIG 13 FIG 14 FIG 12 CHIUSI CLOSED APERTI OPEN A C B D 1 ...
Страница 65: ... Manuale d istruzione AL VOLUMETRICO 65 ...
Страница 66: ... 66 Manual de istrucciones AL VOLUMÉTRICO ...
Страница 67: ... Manuale d istruzione AL VOLUMETRICO 67 ...