background image

Battery Voltage Recorder BVR11 

 

M-B011VR-202-EN 

7

 

3.  Getting Started 

3.1. 

Connecting BVR11 to a Test Object 

 

Before the BVR11 has been connected to a test object (e.g. a battery), the following steps must be taken: 

•  The test object should be examined in case of any visual damages or leakages. 

 

Note: 

Always connect measuring cables to the BVR11 instrument first and then to the test object. When 
disconnecting, always disconnect the cables from the test object first and then from the BVR11. 
Not following these instructions may cause hazardous situations

 

 

 

The red sense cable should be connected to the positive polarity side at the beginning of a battery or a cell 
string,  depending  on  a  test  object  being  measured.  The  black  sense  cable  should  be  connected  to  the 
negative polarity side at the end of the measured string (batteries or cells). 

Any source of interference should be eliminated from the test area, if possible. 

•  To  maximize  the  accuracy  and  measurement  repeatability,  make  sure  that  all  clamps  have  a  good 

connection to the test object and avoid any crossing between the measuring cables. 

 

 

C A U T I O N 

 

For  safety  reasons,  a  connection  of  the  device  should  be  always  established  with  the  test 
object in the way described in this Manual.

 

 

The measuring cables should not be connected after the start of the test.  

 

The measuring cables should not be disconnected before the test is over.  

 
 
 

Figure 3-1: 
Connecting BVR11 to a 
single battery

 

Figure 3-2: 
String measurement 
with BVR11

 

Содержание BVR11

Страница 1: ...BATTERY VOLTAGE RECORDER BVR11 Manual Manual Version M B011VR 202 EN This Manual refers to the firmware version 1 14 Publishing date 2016 08 08...

Страница 2: ...g Started 7 3 1 CONNECTING BVR11 TO A TEST OBJECT 7 3 2 SETTING MEASUREMENT PARAMETERS 8 3 2 1 Main Menu 8 3 2 2 Measurement Menu 9 3 2 3 Memory Menu 11 3 2 4 Settings Menu 12 4 SD Card Initialization...

Страница 3: ...rby objects The BVR11is intended exclusively for the application purposes specified in the Intended Use section The manufacturer and distributors are not liable for any damage resulting from wrong usa...

Страница 4: ...ion module dongle as the recommended accessory In case the Bluetooth cannot establish a communication with DV B Win software please follow the procedure below Disconnect the Bluetooth communication mo...

Страница 5: ...ts as well as to go to the next screen if no changes needed on the active one ENTER button is also used for navigating to the Voltmeter mode or Current probe mode of measurement in Main Menu Use the L...

Страница 6: ...SB serial interface to connect to an external computer if required 5 SD Card To store the test results the BVR11 is equipped with a removable 2 GB Mini SD Card 6 Mains Power Connector The connector fo...

Страница 7: ...f a battery or a cell string depending on a test object being measured The black sense cable should be connected to the negative polarity side at the end of the measured string batteries or cells Any...

Страница 8: ...and 1000 may be selected By default the BVR11 is automatically increasing the string ID and a scan ID number sequentially The user may select a preferred unused or used ID number in which case the pre...

Страница 9: ...a will be overwritten 3 2 2 2 Voltmeter mode By pressing the ENTER button while in the Main menu the BVR11 goes into the Voltmeter mode for continuous measurement of battery voltage In this mode the v...

Страница 10: ...bers 3 1 1 3 1 2 3 1 3 etc In case the user wants to repeat one of previous measurements the return to the previous measurement is enabled by pressing the LEFT button on the device If any of the test...

Страница 11: ...urements After reaching the maximum allowed number of measurements 1 000 scans with maximum of 250 measurements per string the device automatically records the next test data sequence by overwriting m...

Страница 12: ...uired during the Scan Nb 2 of that string When a particular test is selected and the ENTER button is pressed the histogram graph of those particular test results are displayed Figure 3 11 3 2 4 Settin...

Страница 13: ...screen the user can enter Minimum and Maximum voltage limit values for the entire string as well as for individual cells In case the user prefers to use an automatic String limits calculation based on...

Страница 14: ...voltage limits are set to 1 75 V and 2 35 V and the string voltage limits are set for a 24 V battery string to 21 00 V and 28 20 V Language In the Language section the user may select the displayed la...

Страница 15: ...Battery Voltage Recorder BVR11 M B011VR 202 EN 15 If the user is satisfied with the selected options all the selections can be confirmed by pressing ENTER Figure 3 18 Bluetooth selection...

Страница 16: ...If there is no SD card in the SD card slot or if the initialization is not successful the following message will be displayed 4 2 Initialization failure in Measurement menu In case the BVR11 fails to...

Страница 17: ...1 Take a 6 V stable voltage source 6 V battery 2 Connect the BVR11 device and a test battery as shown in the Figure 5 1 3 Set the test on the BVR11 device as described in the Section 3 2 1 go to the...

Страница 18: ...mbers hardware configuration and software revision Exact description of the problem including the test object information error messages and the sequence of events before it appeared List of solutions...

Страница 19: ...should be sent to DV Power freight pre paid unless other arrangements have been authorized in advance by DV Power Customer Service To prepare an instrument for shipment please follow these instruction...

Страница 20: ...ell voltage measuring range 0 30 V DC Measuring range Typical accuracy Resolution 30 V DC 0 1 rdg 0 1 FS 10 mV 500 V DC 0 1 rdg 0 1 FS 100 mV Temperature 50 C 260 C 58 F 500 F Display Type TFT LCD 3 1...

Страница 21: ...98 mm x 46 mm 8 77 in x 3 85 in x 1 81 in Weight 0 5 kg 1 1 lbs Warranty Three years Low Voltage Directive Directive 2014 35 EU CE conform Applicable standards for a class I instrument pollution degre...

Страница 22: ...essories Article No Battery Voltage Recorder BVR11 BVR11X NN 00 DV B Win software including mini USB cable Transport bag and carrying belts Mains power adapter Recommended Article No Sense cables S2 0...

Страница 23: ...e and up to date as possible IBEKO Power AB assumes no responsibility for errors or omissions or for damages resulting from the use of the information contained herein IBEKO Power AB cannot take over...