Operation
18
Operating Instructions 911-211-10 - 00.0 - 10/2020
4.
Insert the new needle into the needle bar (6) until it reaches the end
stop.
Important
The groove (3) must face toward the hook.
5.
Tighten threaded pin (4) (threaded pins (4) and (5) for long needles).
Information
Changing from needle system 328 to 794 or 7X23
1.
Loosen the threaded pin (4).
2.
Pull the needle downwards out of the needle bar (6).
3.
Loosen the threaded pin (5).
4.
Remove the cylinder pin (2).
5.
Insert the long needle into the needle bar (6) until it reaches the end
stop.
6.
Tighten threaded pins (4) and (5).
Changing from needle system 794 or 7X23 to 328:
1.
Loosen threaded pins (4) and (5).
2.
Pull the needle downwards out of the needle bar (6).
3.
Insert the cylinder pin (2) into the hole.
4.
Tighten the threaded pin (5).
5.
Insert the short needle into the needle bar (6) until it reaches the end
stop.
6.
Tighten the threaded pin (4).
Order
After switching to a different needle thickness, adjust the distance
between hook and needle (
Service Instructions
).
Содержание 911-211-10
Страница 1: ...911 211 10 Operating Instructions...
Страница 6: ...Table of Contents 4 Operating Instructions 911 211 10 00 0 10 2020...
Страница 10: ...About these instructions 8 Operating Instructions 911 211 10 00 0 10 2020...
Страница 34: ...Operation 32 Operating Instructions 911 211 10 00 0 10 2020...
Страница 88: ...Programming 86 Operating Instructions 911 211 10 00 0 10 2020...
Страница 108: ...Setup 106 Operating Instructions 911 211 10 00 0 10 2020...
Страница 110: ...Decommissioning 108 Operating Instructions 911 211 10 00 0 10 2020...
Страница 112: ...Disposal 110 Operating Instructions 911 211 10 00 0 10 2020...
Страница 133: ......