Loosen screws (3) and (4). Move the throat plate so that the rule
2.1
(A) = 0,1 mm
according to
fig. 1
or rule 2.2 according to
fig. 2
is accomplished. Tighten the screws.
–
Center the throat plate insert (see chapter 2.9).
–
Set the maximum stitch length (see chapter 2).
–
Set the needle to the position in which it leaves the throat plate
insert. Dismantle the rear cover and loosen screw (6). Set the
needle manually to the position shown in
fig. 3
and tighten
screw (6).
21
EN
A
3
4
5
Fig. 1
Fig. 3
6
3
Fig. 2