Automatic corner knife station (straight pocket)
Service Instructions 755 A/756 A - 00.0 - 02/2019
141
Setting the reference switch
Testing the initial position of the corner knives manually (3)
To set the reference switch:
8. Swivel out the corner knife station.
The distance between the reference switch (6) and the screw (7)
must be 0.5 mm.
9. Loosen the nut (5) at the reference switch (6).
10. Swivel down the reference switch (6) until the switching head lines up
precisely with the nut (5).
11. Tighten the nut (5).
12. Loosen the nut (8).
13. Loosen the screw (7) until the distance between screw (7) and
reference switch (6) is 0.5 mm.
14. Tighten the nut (8).
(5)
- Nut
(6)
- Reference switch
(7)
- Screw
(8)
- Nut
⑤
⑥
⑦ ⑧
Содержание 755 A
Страница 1: ...755 A 756 A Service Instructions...
Страница 8: ...Table of Contents 6 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 12: ...About these instructions 10 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 116: ...Folder 114 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 124: ...Transport carriage 122 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 138: ...Transport clamps 136 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 200: ...Light barriers 198 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 222: ...Endless zipper feed optional 220 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 238: ...Additional equipment 236 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 266: ...Stacker 264 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 438: ...Programming 436 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 450: ...Decommissioning 448 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 452: ...Disposal 450 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 472: ...Technical data 470 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 496: ...Appendix 494 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 497: ......