Folder
Service Instructions 755 A/756 A - 00.0 - 02/2019
113
17.6 Setting the folder detection
Fig. 116: Setting the folder detection
Proper setting
The switch (1) is activated when the folder has reached a distance of 5 mm
from the fabric sliding plate when moving downwards.
To set the folder detection:
1. Open the menu
Service > Multi test > Multi test I/O
and select the input
S9
.
2. Loosen the screw (2).
3. Slide the switch (1) to change its position on the cylinder.
The switch (1) is activated when the folder has reached a distance
of 5 mm from the fabric sliding plate when moving downwards.
4. Tighten the screw (2).
(1)
- Switch
(2)
- Screw
①
②
Содержание 755 A
Страница 1: ...755 A 756 A Service Instructions...
Страница 8: ...Table of Contents 6 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 12: ...About these instructions 10 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 116: ...Folder 114 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 124: ...Transport carriage 122 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 138: ...Transport clamps 136 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 200: ...Light barriers 198 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 222: ...Endless zipper feed optional 220 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 238: ...Additional equipment 236 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 266: ...Stacker 264 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 438: ...Programming 436 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 450: ...Decommissioning 448 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 452: ...Disposal 450 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 472: ...Technical data 470 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 496: ...Appendix 494 Service Instructions 755 A 756 A 00 0 02 2019...
Страница 497: ......