All dimensions are approximate and subject to the limitations of the material used and the methods of manufacture
Page 22
21x F.4020
9x
F.4020.A (cut to suit)
7x
J.1960
Floor installation
FLOOR TRIMS
Floor trims need to be cut to fit
Fix them using 55mm screws at intervals of 300-400mm
Pre-drill holes for screws!
IMPORTANT - For optional extra Floor Insulation please refer to the
information at the back of the manual.
FLOOR BOARDS
Floor boards run at right angles to the bearers
Use 40mm nails and nail through into the bearers beneath
1 nail per connection!
Leave a 5mm expansion gap between the wall and the first
floor board
Leave a 2mm expansion gap between each floor board
Leave a 5mm expansion gap between the wall and the last
floor board
You may need to cut the last floor board
2mm gap
Bearers
Floor boards
Wall logs
Floor trim
55mm screw
Approx. 5mm gap
Standard length
Required length
Cutting line
IMPORTANT - All angle-cut floor boards are supplied in standard length (the longest that
may be required). Those floor boards are required to be cut to suit on site
(single, straight cut) as shown below, to fit in-between the wall and
the door fame, leaving approx. 5mm gap either side.
J.1960
J.1960
J.1960
F.4020.A
F.4020