![dunkermotoren GR 53 SI Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/dunkermotoren/gr-53-si/gr-53-si_instruction-manual_2539791015.webp)
14
Instruction Manual/Betriebsanleitung
GR 53 SI / GR 63 SI
, Version: 1.2 en_de
© 2009 Dunkermotoren GmbH; D-79848 Bonndorf; Germany
6.6.2 Connection via 12-pin connector at
40V version
Connec-
tor-Pin
Connec-
tion
Function
Strand co-
lour of the
connecting
cable with
12-pole
angular con-
nector (*)
E+F
U
E
motor supply
+ 40V DC
red (1 mm
2
)
D
+24V
Logic Supply
green
M+G
Gnd
0 V ground
for U
E
black
(1 mm
2
)
B
IN1
Left
yellow
C
IN2
Right
blue
J
AI+
Analogue set
value N+
(0 ... +10 V)
pink
H
AI-
Analogue set
value N- (re-
ference mass
for N+)
magenta
A
OUT1
Pulse output,
15 pulses/rot.,
(+24 V-swit-
ching)
orange
K
OUT2
Direction of
rotation
hi = left
lo = right
white
L
OUT3
hi =o.k.
lo = fault
OK-Message
brown
(*) Lead colours refers to standard connection cables
of Dunkermotoren.
Note:
Pin connection according to 12V/24V version on
request available
6.6.2 Anschluss über 12-pol. Stecker bei
40 V-Ausführung
Stecker-
Pin
An-
schluss
Funktion
Litzen-
farbe der
Anschluss-
leitung mit
12 pol.
Winkelste-
cker (*)
E+F
U
E
Motorversor-
gung
+40V DC
rot (1 mm
2
)
D
+24V
Logikversor-
gung
grün
M+G
Gnd
0 V Bezugs-
masse für U
E
schwarz (1
mm
2
)
B
IN1
Links
gelb
C
IN2
Rechts
blau
J
AI+
Analogsoll-
wert N+
(0 ... +10 V)
rosa
H
AI-
Analogsollwert
N- (Referenz-
masse für N+)
violett
A
OUT1
Pulsausgang,
15 Pulse/
Umdr.,
(+24 V-schal-
tend)
orange
K
OUT2
Drehrichtung
hi = links
lo = rechts
weiß
L
OUT3
hi = O.k.
lo = Störung
OK-Meldung
braun
(*) Litzenfarben beziehen sich auf Standard Anschluss-
leitungen von Dunkermotoren.
Hinweis:
Steckerbelegung entsprechend der 12V/24V-
Variante sind auf Anfrage möglich
6 Installation / terminal assignment
6 Installation und Anschlussbelegung
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com