XIN 05 switch
Removable guard
Gear tray
WITH BATTERY AND POWER SUPPLY SWITCH OFF :
XEL 80AI, XEL 80VAI, XEL 80SI, XEL80VSI, XEL 300AI, XEL 300VAI, XEL 300 SI and XEL 300 VSI
Those blocks are mounted with automatic switch off; mains, remote control and battery, which allows to open in hazardous area
without dismounting.
CABLE GLAND: Without cable gland for standard delivery.
The luminaire allow to use a ¾ NPT cable gland (3/4 plug fitted), The cable gland installation need to required to standards
EN60079-14 mainly § 14-2 on cable entries.
In marine environments, it is strongly advised to cover the cable gland with a shroud to avoid electrolysis phenomenon.
To ensure the weatherprofness of the connection, check the tightening of the cable with the inner gasket.
During that tightening, ensure that the cable gland body does not rotated upon the junction box cover.
OPENING THE TERMINAL BLOCK
Warning : « DO NOT OPEN WHILE ENERGIZED ».
Remove the cover with the 4 locking screws (Chc M5,
allen wrench N°4)
CONNECTION TO TERMINAL BLOC
Connect the mains, the earth and the + and - remote control with the terminal block
placed on the junction box. Advice: 5x1,5mm2
Recommendation: greatest flexibility cable: 2,5
mm²
.
BLOCK OPENING
ACCESS TO CONTROL GEAR AND LAMPS
Press down the removable guard on XIN 05 switch.
Disconnect the terminal block
Unlock the cover lock system while screwing the CHc locking screw (BTR 3 allen wrench) to switch off automatically the mains
and the battery.
Tip the lock system.
Before opening the threaded cover, the time delays before opening must be elapsed (see
$
I).
Unscrew the threaded cover.
4 Chc M5
Pull out the gear tray
Remove the stop pin with a
screw-driver