10. Optional external aerial
If there is a need of increasing the range instead of the inside wire aerial,
outside aerial should be installed. It is possible to use the optional ANT868 aerial - OB.
The casing of the FLEX868 receiver is adapted to the installation of such an aerial on the
up edge ( side), Fig.39.
11. FLEX868 receiver error codes
FLEX868 receiver programme after identifying the error or breakage shows on
the LED display appropriate error code, according to tab.1.
Error
number
Description
Err.1
In CP option if we choose different type of copied remote than the one to be copied
Err.2
In CP option if we choose to copy the record number where there is no remote or it is its
own record number
Err
Invalid PIN.
Error of physical address readout (MAC address)of WL card (there is no card or it is
switched off (Et.tP=oF).
Er.14
No memory or damage of the memory (M2)
Er.15
No memory or damage of the internal memory
Er.16
RTC clock damage
Tab. 1
FLEX868 receiver error codes
12. Exemplary table of remotes evidence
To manage the remotes especially without physical access to them it is necessary to start and evidence of
remotes assigned to the receiver memory. The example of a table is shown in Table 2. Flex868 receiver in additional
wireless managing option through Wi-Fi WL card (pt. 8) offers modern and comfortable way of managing the evidence of
remote controls and many additional functions.
Reference
number
User
Channel C1
Channel C2
Channel C3
Channel C4
0001
name
button(s)
button(s)
button(s)
button(s)
0002
name
button(s)
button(s)
button(s)
button(s)
0003
name
button(s)
button(s)
button(s)
button(s)
0004
name
button(s)
button(s)
button(s)
button(s)
0005
name
button(s)
button(s)
button(s)
button(s)
0006
0007
0008
0009
0010
0011
0012
0013
0014
0015
0016
0017
0018
0019
0020
Tab. 2
Exemplary table of remotes evidence.
Fig. 39
View of FLEX868 receiver
with optional aerial ANT868-OB.
nstalled on the casing
Содержание cloud FLEX
Страница 1: ...v 1 3 ...
Страница 21: ...21 Fig 20 Securing the menu of the receiver with PIN code bd function in main menu of the receiver ...
Страница 22: ...22 Fig 21 Switching off the security code of main menu bd function in main menu of the receiver ...
Страница 25: ...25 Fig 23 Assigning receiver channels to the manual control output Sr CA function ...
Страница 26: ...26 Fig 24 Programming of manual control output type Sr In function OUTPUT TYPE NO NC ...
Страница 27: ...27 Fig 25 Programming of breach time of manual control output Sr ti function ...
Страница 33: ...33 Fig 30 Galactic function on off Setting the authentication code GALACTIC CODE SETTING RETURN TO MENU ...
Страница 40: ...40 ...