24
5.6. Sr option - receiver INPUT settings. Manual control mode and status signaling mode.
The FLEX868 receiver is equipped with an INPUT input (Fig. 2) that can work in one of two modes: manual
control mode or status signaling mode.
Input parameters that can be changed are:
Sr.CA - assignments of channels to be triggered by this input in the manual control mode (several can be
controlled simultaneously);
Sr.In - input type - NO / NC;
Sr.tI - violation time needed to activate the input;
Sr.St - setting the input into the status signaling mode.
5.6.1. Setting of INPUT parameters
To set the INPUT parameters in sequence:
from the main menu level with the NEXT button select the Sr option and press OK / ESC button of the receiver;
the display will show 'Sr.CA';
go to the 'Sr.In' option using the NEXT button;
press the OK / ESC button, the display shows 'In.no' (fig. 24);
with the NEXT button set the required input type (NC type - 'In.nc', NO type - 'In.no'), accept by pressing OK /
ESC button of the receiver;
use the NEXT button to go to the Sr.tI function; use the OK / ESC button to enter the function - the display will
show 'tI.0' (fig. 25);
with the NEXT button set the required time in the range of 0 ... 9s and confirm with the OK / ESC button;
press and hold OK / ESC button of the receiver to return to the menu of the receiver.
Changing the Sr.In parameter may result in the immediate triggering of the channel(s).
5.6.2. Manual control mode
The manual control mode enables manual switching of the receiver channels after connecting the momentary
button to the A and B screw terminals.
In order to set the input to the manual control mode:
from the main menu level with the NEXT button select the Sr option and press the OK / ESC button of the
receiver; the display will show 'Sr.CA' (fig. 23);
press OK / ESC button;
the display will show 'Sr_x', where 'x' is the channel number associated with the manual control input, if the
manual control input is to control the selected channel, with the NEXT button, set the "C" ('Sr.Cx') marker in front
of the channel number, if the channel is not to be switched on, set the "_" ('Sr._x') marker; the number of the
edited channel can be changed with the NEXT button by pressing it longer;
accept the channel configuration by pressing OK / ESC;
press and hold OK / ESC button of the receiver to return to the menu of the receiver.
Setting the active channel for the manual control input ('Sr.CA') automatically disables the status signaling
mode ('Sr.St').
5.6.3. Status signaling mode
The signaling mode informs about the input status.
To set the input to the status signaling mode, follow the steps below:
from the main menu level, with the NEXT button, select the Sr option;
press the OK / ESC button, select the 'St' sub-option with the NEXT button (fig. 26);
in the 'St' sub-option set the parameter value to 'on' with the NEXT button;
confirm the selection by pressing OK / ESC;
press and hold OK / ESC button of the receiver to return to the menu.
Depending on the setting of the input type 'no' / 'nc', the active mode is shorting or opening the terminals A and B of the
input marked INPUT. When the state of the INPUT input is changed to active, the message 'Sr.on' appears on the receiver's
display. When the state of the INPUT input is changed to inactive, the message 'Sr.oF' appears on the display.
Włączenie trybu sygnalizacji stanu usuwa wszystkie powiązania kanałów z wejściem sterowania ręcznego.
Содержание cloud FLEX
Страница 1: ...v 1 3 ...
Страница 21: ...21 Fig 20 Securing the menu of the receiver with PIN code bd function in main menu of the receiver ...
Страница 22: ...22 Fig 21 Switching off the security code of main menu bd function in main menu of the receiver ...
Страница 25: ...25 Fig 23 Assigning receiver channels to the manual control output Sr CA function ...
Страница 26: ...26 Fig 24 Programming of manual control output type Sr In function OUTPUT TYPE NO NC ...
Страница 27: ...27 Fig 25 Programming of breach time of manual control output Sr ti function ...
Страница 33: ...33 Fig 30 Galactic function on off Setting the authentication code GALACTIC CODE SETTING RETURN TO MENU ...
Страница 40: ...40 ...