3. SAFETY

-

RELATED REGULATIONS

 

For connecting, programming and servicing, the fol-
lowing regulations must be observed (the list is not 
exhaustive).

 

• 

EN 12453 (Safety in use of power operated doors  

-

 

Requirements)

 

• 

EN 12445 (Safety in use of power operated doors 

-

 

Test methods)

 

• 

EN 12978 ((Industrial commercial and garage doors 
and gates 

-

 safety devices for power operated doors  

-

 Requirements and test methods)

 

 

References to additional, additionally accepted stand-
ards must also be observed, such as:

 

• 

EN 60204

-

1 (Safety of machinery, electrical equip-

ment of machines, part 1: general requirements) 

 

• 

EN 12100

-

1 (Safety of machinery, basic concepts, 

general principles for design. Basic terminology, 
methodology) 

 

• 

EN 60335

-

1 (Household and similar electrical appli-

ances 

-

 Safety) 

 

• 

EN 60335

-

2

-

103 (Particular requirements for drives 

for gates, doors and windows)

 

• 

Committee for Workplaces (ASTA) 

 

• 

Workplace regulation ASR A1.7 

(“

Doors and gates

“) 

 

4. SAFETY INSTRUCTIONS

 

 

DANGER !

 

Failure to comply with the documentation could result in

 

life

-

threatening danger!

 

Be sure to follow all the safety instructions in this docu-
ment.

 

DANGER !

 

Life

-

threatening danger due to electric shock!

 

• 

It is vital that you disconnect the operator system 
from the power supply before commencing cabling 
work. Take measures to ensure that the power sup-
ply remains disconnected for the duration of the 
work.

 

NOTICE !

 

For a three

-

phase current, a clockwise rotating field is 

required.

 

WARNING !

 

• 

Ensure that children can not play with the door con-
trols or the hand transmitter.

 

• 

Before setting the door in motion, make sure that no 
persons or objects are within the danger zone of the 
door.

 

• 

Check all the existing emergency command devices.

 

• 

Pay attention to potential crushing and shearing 
zones in the door system.

 

• 

Never touch a running door, the guide rail or any 
moving parts.

 

INFORMATION !

 

For a permanent connection, an all

-

pole main switch 

must be used.

 

WARNING !

 

• 

The control and the drive must be installed with its 
intended covers and guards. It is important to en-
sure the correct fit of any seals and couplings are 
tightened correctly.

 

• 

The mains voltage must correspond to the voltage 
stated on the type plate.

 

• 

The mains voltage must be the same as the voltage 
of the drive.

 

• 

For a three

-

phase connection, only 3

-

way automatic 

circuit breakers (10A) may be used. 

 

• 

Before switching on the controls for the first time, a 
check must be carried out after completing the wir-
ing to ensure that all the motor connections at the 
motor and at the controls are securely fixed.

 

 

• 

SAFETY RELAYS:

 

• 

If the control unit is a version without three safety 
relays, the door manufacturer/installer is responsi-
ble of preventing any dangerous situation if one of 
the contactors is welded.

 

Содержание CONTROL V7E

Страница 1: ...04 2022 Version 1 DoorTec Deutschland www doortec online nderungen vorbehalten Subject to Modifications OPERATION MANUAL CONTROL V7E VERSION 29 22...

Страница 2: ...essarily to scale 2 2 Using the equipment for its intended purpose The control V7E is designed only for controlling gates and doors with mechanical or digital end position sys tems For other applicati...

Страница 3: ...om the power supply before commencing cabling work Take measures to ensure that the power sup ply remains disconnected for the duration of the work NOTICE For a three phase current a clockwise rotatin...

Страница 4: ...that the direction of rota tion of the gear motor is correct and that all protective devices are functioning 5 1 Electrical installation 5 2 HOW TO program The door will always run in hold to run mod...

Страница 5: ...age Operation mode 7 Reaction Failure on photo or Safety edge 7 Selection of limits 7 Learning Electronic Limit Open 8 Fine Tuning of electronic Limit Open 8 Learning Electronic limit CLOSE 8 Fine tun...

Страница 6: ...r Description Page Auto close 11 Car wash function 11 Forced closing 12 GO function Step 12 Interlock function ON OFF 12 Run time control 12 Reverse time safety edge 12 Reserve time photo 13 Service c...

Страница 7: ...hold to run mode when programming Reaction Failure on photo or Safety edge 00 Hold to run operation not possible when failure on photo or safety edge The door cannot close when there is an error on p...

Страница 8: ...e open 1 4 less open Press OPEN or CLOSE push button to change value If the value is changed Press STOP push button Display shows RUN Test the fine tuning by running the door up and down Press the STO...

Страница 9: ...o switch NC type in terminal 15 16 Short circuit terminal 15 16 parallel connected by mechanical switch to ON OFF this function Electronic limits Value 00 selected in parameter 11 ON OFF controlled by...

Страница 10: ...contact 05 Wireless safety edge with test function X20 After run 00 No after run 00 After run active after run time 0 01 0 50 sec Monitoring of PNE DW air switch safety edge is automatically selected...

Страница 11: ...ning from close to open posi tion The door will stop when the photo is no longer blocked and the control unit will change back to parameter number automatically Auto close Note that impulse close must...

Страница 12: ...s a connect ing bridge between X3 20 22 parameter 31 02 Interlock function Only when auto close is selected parameter 32 00 Interlock function OFF 01 Interlock function ON Run time control 00 No run t...

Страница 13: ...0 open cycles before service Reset for new countdown or selecting value Press STOP to select parameter value Press OPEN or CLOSE to select value Press STOP again minimum 2 sec CLR is shown 2 sec in di...

Страница 14: ...mming mode on DIL switch no 1 This will clear the SER error If the door is running again in 1 sec without command when power is on then the PCB is defect 4 Calculation error Check that parameter 11 va...

Страница 15: ...leshooting OPEN push button active Normal symbol as an aid in programming and troubleshooting Activation of loop detector will also show this symbol CLOSE push button active Normal symbol as an aid in...

Страница 16: ...emented to 0 Reset for new countdown Photo Failure in photo circuit Test cycle after last stop failed Press stop to start new test Safety edge Failure in edge circuit Test cycle after last stop failed...

Страница 17: ...o 999000 and the least significant digits 000 999 Example shown is 362 and 086 362086 door openings Press STOP to see last 10 errors or exit by switching DIL switch 2 to off Last 10 Errors Press OPEN...

Страница 18: ...dary safety edge D7 LED Power X5 Key pad X24 Power supply selection D10 LED Stop X6 Antenna radio receiver K1 Contactor OPEN D12 LED limit CLOSE X7 Plug in module radio receiver K2 Contactor CLOSE D13...

Страница 19: ...g required The supply voltage of the transmitter is switched off to test the photocell Without testing the sensor can not be used 10 CONNECTIONS X3 10 1 Command devices 6 wire connection The LED light...

Страница 20: ...grey 21 Input black 22 Input white 10 9 Additional photo beam Photo 1 X12 Parameter 31 01 10 10 Potential Free Contact K3 OPTION INFORMATION The polarity of the test signal must be considered The sig...

Страница 21: ...E terminals N X1 L1 L X1 L3 N linked with a wire Motor connection Phase open direction X2 U Phase close direction X2 V Common N X2 W 10 13 Light curtain P N P transistor OSE connection No Semiconduc t...

Страница 22: ...AC 4 kW Max motor load by 3 x 230V AC 2 3 kW Max motor load by 1 x 230V AC 1 5 kW Max motor current 8 5 A Operating duty cycle 60 at max 120 s runtime Consumption control Max 13 VA Control voltage 24...

Страница 23: ...been used EN 60335 1 2012 AC 2014 Household and similar electrical appliance Safety EN 60335 2 103 2015 Household and similar electrical appliance Safety Particular requirement for drives for gates do...

Страница 24: ...utschland www doortec online nderungen vorbehalten Subject to Modifications Chain Wheel Operators Controls Safety Systems Accessories DoorTec Sectional Door Rolling Shutter Operators Operators PRODUCT...

Отзывы: