22
DoorTec Deutschland | www.doortec.online
04/2022
-
Version 1
Änderungen vorbehalten | Subject to Modifications
11. TECHNICAL DATA
Enclosure data:
293 x 190 x 110 mm, ABS
Protection:
IP65 (with appropriate cable glands)
Installation:
Vertical on a vibration free and flat wall, min. hight: 1.1 m
Mass:
ca. 1.8 kg
Humidity:
Up to 93% RH non
-
condensing
Temperature range:
Operating:
-
10° C
…
+50°C
PCB dimension:
225 x 163 x 80 mm
Supply voltage:
400 V/AC ± 10% L1,L2,L3,N,PE
230 V/AC ± 10% L1,L2,L3,PE
230 V/AC ± 10% L, N
50/60Hz, Mains fuse max: 3 x 10A
Transformer:
Max 13 VA , VDE 0570/EN61558
Primary 230VAC winding is thermal protected by built
-
in thermal transform-
er fuse. Both secondary windings are overload protected by multifuses.
Motor output:
Max motor load by 3 x 400V/AC: 4 kW
Max motor load by 3 x 230V/AC: 2.3 kW
Max motor load by 1 x 230V/AC: 1.5 kW
Max motor current: 8,5 A
Operating duty cycle:
60% at max. 120 s runtime
Consumption control:
Max. 13 VA
Control voltage:
24 VDC, max. 250 mA; protected by polyfuse
Electronic limits:
RS485, Data+ Data
-
, terminated with 120 Ohm
Emergency stop, Stop, Thermo
Function as normal stop command and disconnect power to contactor coils.
Safety edge input:
•
PNE/air switch
•
Electric type
-
8k2 termination ± 10%
•
Optical type (Fraba OSE or Dalmatic TSS/RSS)
Performance level C, Category 2
Optical safety edge:
Input voltage high (green):
2.5
-
5.0 Volt
Input voltage low (green):
< 0.5
Volt
Input frequency range (green):
250
–
2000
Hz. (50% duty
-
cycle)
Pulse interval maximum (green):
7.0 ms (when not 50% duty cycle)
Photo input (X3
-
19,20,21,22 ):
External photo, 24VDC (e.g. self contain photo cell)
24 VDC Output (X3
-
18, X3
-
19):
24VDC ± 20% (non
-
regulated), Max load: 250mA
Option relay output (K3 + X17):
Change over contact: 230VAC/5A