background image

 

 

2             

 

DoorTec Deutschland  |  www.doortec.online

 

04/2022

 

-

 

Version 1  

 

 

Änderungen vorbehalten  |  Subject to Modifications

 

 

2.4 Target group

 

Only qualified and trained service engineers shall in-
stall the control.

 

Only qualified and trained electricians shall connect 
and carry out the electrical maintenance.

 

Qualified and trained professionals have knowledge of 
the general and specific safety and accident preven-
tion regulations, of the relevant regulations and stand-
ards, training in the use and maintenance of adequate 
safety equipment, as well as the ability to recognize 
hazards associated with their work.

 

2.5 Key to symbols

 

 

1. CONTENTS

 

1.

 

Contents 

 ................................................... 

2

 

2.

 

General instructions 

 ................................. 

2

 

3.

 

Safety related regulations 

 ........................ 

3

 

4.

 

Safety instructions 

.................................... 

3

 

5.

 

Initial Operation 

 ........................................ 

4

 

6.

 

LED Codes 

 ............................................. 

14

 

7.

 

Run mode / error codes 

 ......................... 

15

 

8.

 

Electronic counter and last 10 errors 

 ..... 

17

 

9.

 

PCB

-

overview 

 ........................................ 

18

 

10.

 

Connections 

 ........................................... 

19

 

11.

 

Technical Data 

 ....................................... 

22

 

12.

 

Declaration of conformity 

 ....................... 

23

 

2 GENERAL INSTRUCTIONS

 

2.1 Original operating instructions

 

• 

Copyright protection: any reproduction is permitted 
only with permission of Tornado Antriebstechnik 
GmbH.

 

• 

Changes in the interest of technical progress are 
reserved.

 

• 

All dimensions are in millimetres, drawings are not 
necessarily to scale.

 

2.2 Using the equipment for its intended purpose

 

The control V7E is designed only for controlling gates 
and doors with mechanical or digital end position sys-
tems. 

 

For other applications, the controller must be consult-
ed with the manufacturer.

 

2.3 Warranty

 

The function and safety of the equipment is only guar-
anteed if the warning and safety instructions included 
in these operating instructions are adhered to. 

 

The manufacturer is not liable for any personal injury 
or damage to property that occurs as a result of the 
warning and safety instructions being disregarded.

 

The CE declaration and warranty is voided by chang-
es such as unauthorized attachments, modifications or 
rewiring goes out.  Only original spare parts shall be 
used.

 

These parts serve to maintain the quality and safety of 
the machine. Changes are only permitted after consul-
tation with the manufacturer.

 

DANGER !

 

Safety notice indicating a danger that will directly result 
in death or severe injury.

 

WARNING !

 

Safety notice indicating a danger that could result in 
death or severe injury.

 

CAUTION !

 

Safety notice indicating a danger that could result in 
slight or moderate injuries.

 

NOTICE !

 

Safety notice indicating a danger that could result in 
damage to property or in irreparable damage to the 
product

 

INFORMATION !

 

Reference to a check that needs to be carried out or to 
separate documents that must be observed.

 

Содержание CONTROL V7E

Страница 1: ...04 2022 Version 1 DoorTec Deutschland www doortec online nderungen vorbehalten Subject to Modifications OPERATION MANUAL CONTROL V7E VERSION 29 22...

Страница 2: ...essarily to scale 2 2 Using the equipment for its intended purpose The control V7E is designed only for controlling gates and doors with mechanical or digital end position sys tems For other applicati...

Страница 3: ...om the power supply before commencing cabling work Take measures to ensure that the power sup ply remains disconnected for the duration of the work NOTICE For a three phase current a clockwise rotatin...

Страница 4: ...that the direction of rota tion of the gear motor is correct and that all protective devices are functioning 5 1 Electrical installation 5 2 HOW TO program The door will always run in hold to run mod...

Страница 5: ...age Operation mode 7 Reaction Failure on photo or Safety edge 7 Selection of limits 7 Learning Electronic Limit Open 8 Fine Tuning of electronic Limit Open 8 Learning Electronic limit CLOSE 8 Fine tun...

Страница 6: ...r Description Page Auto close 11 Car wash function 11 Forced closing 12 GO function Step 12 Interlock function ON OFF 12 Run time control 12 Reverse time safety edge 12 Reserve time photo 13 Service c...

Страница 7: ...hold to run mode when programming Reaction Failure on photo or Safety edge 00 Hold to run operation not possible when failure on photo or safety edge The door cannot close when there is an error on p...

Страница 8: ...e open 1 4 less open Press OPEN or CLOSE push button to change value If the value is changed Press STOP push button Display shows RUN Test the fine tuning by running the door up and down Press the STO...

Страница 9: ...o switch NC type in terminal 15 16 Short circuit terminal 15 16 parallel connected by mechanical switch to ON OFF this function Electronic limits Value 00 selected in parameter 11 ON OFF controlled by...

Страница 10: ...contact 05 Wireless safety edge with test function X20 After run 00 No after run 00 After run active after run time 0 01 0 50 sec Monitoring of PNE DW air switch safety edge is automatically selected...

Страница 11: ...ning from close to open posi tion The door will stop when the photo is no longer blocked and the control unit will change back to parameter number automatically Auto close Note that impulse close must...

Страница 12: ...s a connect ing bridge between X3 20 22 parameter 31 02 Interlock function Only when auto close is selected parameter 32 00 Interlock function OFF 01 Interlock function ON Run time control 00 No run t...

Страница 13: ...0 open cycles before service Reset for new countdown or selecting value Press STOP to select parameter value Press OPEN or CLOSE to select value Press STOP again minimum 2 sec CLR is shown 2 sec in di...

Страница 14: ...mming mode on DIL switch no 1 This will clear the SER error If the door is running again in 1 sec without command when power is on then the PCB is defect 4 Calculation error Check that parameter 11 va...

Страница 15: ...leshooting OPEN push button active Normal symbol as an aid in programming and troubleshooting Activation of loop detector will also show this symbol CLOSE push button active Normal symbol as an aid in...

Страница 16: ...emented to 0 Reset for new countdown Photo Failure in photo circuit Test cycle after last stop failed Press stop to start new test Safety edge Failure in edge circuit Test cycle after last stop failed...

Страница 17: ...o 999000 and the least significant digits 000 999 Example shown is 362 and 086 362086 door openings Press STOP to see last 10 errors or exit by switching DIL switch 2 to off Last 10 Errors Press OPEN...

Страница 18: ...dary safety edge D7 LED Power X5 Key pad X24 Power supply selection D10 LED Stop X6 Antenna radio receiver K1 Contactor OPEN D12 LED limit CLOSE X7 Plug in module radio receiver K2 Contactor CLOSE D13...

Страница 19: ...g required The supply voltage of the transmitter is switched off to test the photocell Without testing the sensor can not be used 10 CONNECTIONS X3 10 1 Command devices 6 wire connection The LED light...

Страница 20: ...grey 21 Input black 22 Input white 10 9 Additional photo beam Photo 1 X12 Parameter 31 01 10 10 Potential Free Contact K3 OPTION INFORMATION The polarity of the test signal must be considered The sig...

Страница 21: ...E terminals N X1 L1 L X1 L3 N linked with a wire Motor connection Phase open direction X2 U Phase close direction X2 V Common N X2 W 10 13 Light curtain P N P transistor OSE connection No Semiconduc t...

Страница 22: ...AC 4 kW Max motor load by 3 x 230V AC 2 3 kW Max motor load by 1 x 230V AC 1 5 kW Max motor current 8 5 A Operating duty cycle 60 at max 120 s runtime Consumption control Max 13 VA Control voltage 24...

Страница 23: ...been used EN 60335 1 2012 AC 2014 Household and similar electrical appliance Safety EN 60335 2 103 2015 Household and similar electrical appliance Safety Particular requirement for drives for gates do...

Страница 24: ...utschland www doortec online nderungen vorbehalten Subject to Modifications Chain Wheel Operators Controls Safety Systems Accessories DoorTec Sectional Door Rolling Shutter Operators Operators PRODUCT...