8. ELECTRONIC COUNTER AND LAST 10 ERRORS
To select counter or error history –
Close the door and switch DIL switch 2 to ON.
The door cannot be moved when display status is active!
Electronic Counter
The display is flashing between and the most significant digits (1000 to
999000) and the least significant digits (000 –
999).
Example shown is (362 and 086) = 362086 door openings
Press STOP to see last 10 errors or exit by switching DIL switch 2 to off.
Last 10 Errors
Press OPEN (up) to select newer error.
Press CLOSE (down) to select older error.
If there is no errors the display will show:
By the end of the registered 10 errors the display will show::
Upper end
Lower end
Switch DIL switch 2 to OFF to get out of
”
display status
”.
Reset of last 10 errors by pressing OPEN at least 10 sec. when
“
upper end
”
symbol is shown.
Exit by switching DIL switch 2 to off.