The generic identifier will be sent with 98 as it's zone number, this is a special
combination recognized by
Connect 24
as a generic event. When the generic
zone reporting toggle is disabled, each zone alarm for each zone type will then
send it's own identifier.
Default -
ON
.
[21] System Event Communication Options
NOTE:
Section [20], Option [7] must be enabled for these events to be communicated.
Option 1 - Input Supply Failure
All Modes
If AC power is absent or if DC power drops below 8.8V
DC
on the RED and BLK
terminals, a
trouble will be sent after the delay programmed in section
[22]
has
expired.
Default -
ON,
Option 2 - Low Battery
All Modes
If the battery voltage drops below 5.72V
DC
a trouble will be sent to
Connect 24
.
When the battery voltage rises to 5.87V
DC
the system will send a restore.
Default -
ON.
Option 3 - Skyroute CL3050 Tamper
All Modes
Removing the cover on the Skyroute CL3050 will send a tamper reporting code
to
Connect 24
.
Default -
OFF
.
Option 4 - PC5108 Module Fault
Mode 3
Indicates a Keybus communications fault condition.
Default -
OFF.
Option 5 - PC5108 Tamper
Mode 3
Removing the cover on the PC5108 will send a tamper reporting code to
Con-
nect 24
.
Default -
OFF.
[22] Input Supply Fail TX Delay
All Modes
This value determines the delay (default 0700 = 7 hrs) before an input supply fail-
ure reporting code is sent if programmed. See Section [21]
,
Option [1] and Sec-
tion [20], Option [2].
Default -
0700 (=7 hrs)
[23] Generic Zone Reporting Timer
Modes 2, 3
This hex value determines the delay before a generic zone reporting code is sent,
if programmed in Section 20 Option 8.
Note:
There are four separate timers for Burglary, Fire, Panic and Supervisory;
the delay programmed is the same for each timer.
Default -
1E (300 seconds / 5 minutes) Range equals 01-FF Hex seconds x 10