P R O G R A M D E S C R I P T I O N S
36
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Transmission Delay Enable ............................ Sections [101] to [132], Option [7]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Transmission Delay Time ............................... Section [370]
5.19
Keypad Backlighting
The keys of all the keypads can be backlit to provide easy viewing in dim lighting conditions. If the
Keypad Backlighting Option
is enabled the keys will be illuminated.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Keypad Backlighting Option .......................... Section [016], Option [5]
5.20
Arming / Disarming Options
If the
Arm/Disarm Bell Squawk
option is enabled the panel will squawk the alarm output once upon
arming and twice upon disarming. The
Opening After Alarm Keypad Ringback
option will give you the
ability to beep the keypad 10 times rapidly if the panel is disarmed after an alarm occurred. The
Opening
After Alarm Bell Squawk
option will give you the ability to squawk the bell output 10 times rapidly if the
panel is disarmed after an alarm occurred.
Closing Confirmation
, if enabled, will cause the keypad to beep 10 times rapidly after the closing
reporting code has been transmitted to central station.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Arm/Disarm Bell Squawk ............................... Section [014], Option [1]
Opening After Alarm Keypad Ringback ......... Section [381], Option [1]
Opening After Alarm Bell Ringback ............... Section [381], Option [2]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Closing Confirmation ..................................... Section [381], Option [4]
5.21
Automatic Arming
There are two different Auto-Arming methods available. Each Partition can be programmed to Auto-Arm at
a specific time every day if it is in the disarmed condition. Also a Partition can also be programmed to
Auto-Arm if no activity is registered for a programmed number of minutes.
Before the Auto-Arm at a specific time function will work correctly the present
Time of Day
must be
programmed.
When the internal panel clock matches the
Auto-Arm Time
the panel will check the status of the Partition.
If armed, the panel will do nothing until the next day at the
Auto-Arm Time
, when it will check again.
If disarmed the panel will sound the buzzer of all keypads assigned to the partition for one minute. If a
valid User Code is entered the Auto-Arm will be aborted. The panel will also transmit an
Auto-Arm Abort
Reporting Code
if programmed.
If no code is entered the panel will Auto-Arm. If a zone is violated the panel will transmit a
Partial Closing
Reporting Code
if programmed to indicate the system was not secure. If the zone is restored the panel
will add the zone back into the system.
If the
No Activity Arm
option for a partition is programmed with a number other than 000, the partition will
Auto-Arm if no activity is detected for the programmed number of minutes.
The timer will begin when a delay type zone assigned to the partition is secured. The timer is stopped if
any zone assigned to the partition is tripped. The timer will restart when a delay type zone is again
restored.
When the timer expires the panel will sound the buzzer of all keypads assigned to the Partition for one
minute. If any key is pressed, the Auto-Arm will be aborted.
Zones assigned to both Partitions (Global Zones) will not stop the timer.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Time Date .......................................................
Auto-Arm Time ...............................................
Auto-Arm Cancel Reporting Code ................. Section [348]
Partial Closing Reporting Code ..................... Section [343]
No Activity Arm (Partition 1) .......................... Section [162]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○