P R O G R A M D E S C R I P T I O N S
35
If
Exit Delay Termination
is enabled the panel will monitor the Delay zones during exit delay. If a Delay
type zone is violated then secured during the exit delay, the exit delay will be terminated and the panel will
be armed immediately.
To prevent false alarms on exit the PC5010, use the built-in feature
Audible Exit Fault
. If a delay type zone
is violated within 4 seconds after the exit delay has expired, the panel will sound the entry delay warning
through the keypad and siren alerting the customer that an improper exit was made. If the panel is
disarmed within the entry delay no signal is sent. If not, the panel will continue to sound the alarm and send
a signal to central station.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Audible Exit Delay ......................................... Section [014], Option [6]
Bell Squawk on Exit Delay ............................. Section [014], Option [3]
Exit Delay Termination ................................... Section [014], Option [7]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Bell Squawk on Entry Delay .......................... Section [014], Option [4]
5.16
Event Buffer
The panel will store the last 128 events that have occurred on the system. Each event will contain the time,
date, partition and the event itself along with the zone number, user code number or any other information
pertaining to the event.
If the
Event Buffer Follows Swinger Shutdown
feature is enabled the event buffer will not store events
after the swinger shutdown level has been reached. This will prevent the panel from overwriting the entire
buffer if a problem exists.
(See
Section 5.17 “Swinger Shutdown”
The event buffer can be viewed three different ways. It can be viewed through an LCD keypad, printed on-
site using the PC5400 printer module
(See
Section 5.29 “On-Site Printer”
) or it can be uploaded through the
DLS software.
5.16.1
Viewing the Event Buffer through the LCD Keypad
The following is the procedure for viewing the event buffer through the LCD keypad:
Step 1 - Enter [
✱
] [6] [Master Code]
Step 2 - Select ‘View Event Buffer’
The keypad will display the Event Number, Partition, Time and Date of the event in question. Use the [
✱
]
key to toggle between this information and the event itself. Use the arrow keys (<>) to scroll through the
events in the buffer.
When you have finished viewing the event buffer press the [#] key to exit.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Event Buffer Follows Swinger Shutdown ...... Section [013], Option [7]
5.17
Swinger Shutdown
The swinger shutdown feature is designed to prevent a runaway communicator from tying up the central
station. Different limits can be programmed for
Zone Alarms
,
Zone Tampers
and
Maintenance
signals.
After the panel has communicated the programmed number of transmissions for an event it will no longer
report that event until the swinger shutdown is reset.
For example, the swinger shutdown limit for Zone Alarms is set to [003]. The panel will not send more than
3 alarm signals for each zone with a swinger attribute until the swinger shutdown is reset.
Swinger Shutdown
will be reset when the panel is armed or every day at midnight. Once reset, the panel
will again communicate normally.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Swinger Shutdown Limit (Alarms) ................. Section [370]
Swinger Shutdown Limit (Tampers) .............. Section [370]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Swinger Shutdown Limit (Maintenance) ........ Section [370]
5.18
Transmission Delay
If
Transmission Delay
is selected for a zone the panel will delay reporting the alarm for the number of
seconds programmed for
Transmission Delay Time
. If the panel is disarmed before the delay time
expires the panel will not report the alarm to central station. If the panel is not disarmed in time the panel
will communicate normally.
This is a global feature.