G E T T I N G S T A R T E D
12
2.9.7
LINKS Supervisory
(Shall not be used on UL Listed systems)
If the LINKS1000 cellular communicator is being used a zone may be configured for LINKS Supervisory
(See
Section 5.1 “Zone Definitions”
). If the LINKS1000 experiences a trouble it will violate the zone,
causing the panel to report the event to central station.
The zone programmed as LINKS Supervisory ALWAYS requires a single EOL resistor (5.6K) and must be
wired according to the following diagram:
Ω (
Ω
2.9.8
LINKS Answer
(Shall not be used on UL Listed systems)
If the LINKS1000 cellular communicator is being used a zone may be configured for LINKS Answer to
allow downloading to be performed in the event of phone line failure.
When the LINKS receives a phone call it will activate the RING terminal on the LINKS circuit board. This
terminal can be used to violate a zone programmed as LINKS Answer
Section 5.1 “Zone Definitions”
),
causing the panel to seize the phone line and begin communication with the downloading computer.
The zone programmed as LINKS Answer ALWAYS requires a single EOL resistor (5.6K) and must be wired
according to the following diagram:
Ω (
Ω