P R O G R A M D E S C R I P T I O N S
28
The Pager Format cannot be used with the LINKS1000 cellular communicator.
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Communicator Format Options ...................... Section [360]
○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○
Communicator Call Direction Options ........... Section [361] to [368]
5.7
Communicator - Reporting Codes
The panel can be programmed to report events to a central station. The panel will send the reporting code
programmed for the event.
Reporting codes can be one or two digits and can use HEX digits (A through F). The following is a description of
the different reporting codes that can be programmed and when the events will be reported to central station.
5.7.1
Zone Alarm
The panel will transmit the
Zone Alarm
Reporting Code for a zone when the zone goes into alarm. 24 hour
type zones will go into alarm whether the panel is armed or disarmed and report to the central station. All
other zone types will only go into alarm if the panel is armed.
5.7.2
Zone Restoral
If the
Restoral on Bell Timeout
option is selected the panel will send the
Zone Restoral
Reporting Code
for the zone when the alarm output times out AND the zone is secure. If the zone is not secured when the
alarm output times out the panel will send the restoral immediately after the zone is secured.
If the
Restoral on Bell Timeout
option is not selected the panel will immediately send the
Zone Restoral
Reporting Code when the zone is secured or when the panel is disarmed, regardless if the alarm output is
active or not.
24 Hour type zones will report the restoral immediately after the zone is secured.
5.7.3
Closings
The panel will transmit a
Closing
Reporting Code to indicate a Partition(s) is armed. A different reporting
code can be transmitted for each User Code, Partition Master Code and System Master Code to identify
who armed the Partition(s).
A
Partial Closing
Reporting Code will be transmitted if a Partition is armed with zones manually
bypassed. The code will also be transmitted if a Partition Auto Arms with zone(s) in violation.
A
Special Closing
Reporting Code will be transmitted if the Partition(s) is armed using any of the following
methods:
• Quick Arm
• Arming via the DLS Software
• ‘Away’ Function Key arming
• Auto Arm
• Arming via keyswitch
• ‘Stay’ Function Key arming
• Arming with the Maintenance Code
A
Closing by Duress Code
Reporting Code will be transmitted in addition to the Duress reporting code if
a Partition(s) is armed using a Duress Code.
A
Recent Closing
Reporting Code will be transmitted if an alarm occurs within 2 minutes of the exit delay
expiring.
5.7.4
Openings
The panel will transmit an
Opening
Reporting Code to indicate a Partition(s) has been disarmed. A
different reporting code can be transmitted for each User Code, Partition Master Code and System Master
Code to identify who disarmed the Partition(s).
A
Special Opening
Reporting Code will be transmitted if the Partition(s) is disarmed using any of the
following methods:
• Disarming using the Maintenance Code
• Disarming via the DLS Software
• Disarming via keyswitch
An
Opening After Alarm
Reporting Code will be transmitted in addition to the opening when the
Partition(s) is disarmed after an alarm has occurred.
An
Opening by Duress
Reporting Code will be transmitted in addition to the Duress reporting code if a
Partition(s) is disarmed using a Duress Code.
5.7.5
Tampers
If the panel is programmed for Double EOL zones (See
Zone
Tamper Alarm
Reporting Code if an open condition is present on a zone. A different reporting code can be
programmed for each zone for identification. The
Zone Tamper Restoral
Reporting Code will be transmitted
immediately when the tamper condition is restored.
A
General System Tamper
Reporting Code will be transmitted when the tamper zone on any module is
violated. The
General System Tamper Restoral
Reporting Code will be transmitted when the tamper
zone on the module is restored.