S E C T I O N  1

1.1

Specifications

Control Panel Specifications

Flexible Zone Configuration:

• 8 Fully Programmable Zones
• 37 Access Codes: 32 User, 1 System Master, 2 Partition Master and 2 Duress
• Expandable to 32 Zones
• Hardwired expansion available using the PC5108 Eight Zone Expansion Module
• Wireless expansion available using the PC5132 Wireless Zone Expansion Module (up to 32 wireless

zones, 900MHz, True Spread Spectrum Technology, Fully Supervised)

• Normally Closed, Single EOL, or Double EOL zone supervision
• 2-Wire Smoke Zone
• 27 Zone Types, 8 Programmable Zone Options
• 2 Partitions

Audible Alarm Output:

• Supervised Bell Output (current limited at 3 amps), 12 V

DC

• Steady or Pulsed Output

EEPROM Memory:

• Will not lose programming or system status on complete AC and Battery failure

Programmable Outputs:

• Up to 14 Programmable Voltage Outputs, 18 programmable options
• One High Current (300 mA) PGM output with 2 wire smoke detector capability on main panel
• Maximum Loop Current is 1.5 mA when the 2-wire smoke detector configuration is used
• One Low Current (50 mA) PGM output on main panel
• Eight Additional Low Current (50 mA) PGM outputs available using the PC5208 module
• Four High Current (1 Amp) PGM outputs Available Using the PC5204 module
• 1 PC5204 Output Fully Supervised for Siren Output

Powerful 1 Amp Regulated Power Supply:

• 500 mA Auxiliary Supply, 12 V

DC

• Positive Temperature Coefficient (PTC) components replace fuses
• Supervision for loss of AC Power, Low Battery
• Internal Clock Locked to AC Power Frequency

Power Requirements:

• Transformer = 16.5 VAC, 40VA
• Battery = 12 volt 4 Ah minimum rechargeable sealed lead acid

Remote Keypad Specifications:

• 4 Different Keypads Available:

- PC5508/KP5508 8 Zone LED Keypad

- PC5516/KP5516 16 Zone LED Keypad

- PC5532/KP5532 32 Zone LED Keypad

- LCD5500/KPL5500 Alphanumeric Keypad

• Each Keypad has 5 Fully Programmable Function Keys

• Connect up to 8 Keypads

• Four Wire (Quad) Connection to Keybus

• Built in Piezoelectric Buzzer

Digital Communicator Specifications:

• Supports all Major Formats including SIA and Contact ID

• Event Initiated Personal Paging

• 3 Programmable Phone Numbers

• 2 Account numbers

• Supports LINKS1000 Cellular Communication

• DTMF and Pulse Dialing

• DPDT Line Seizure

• Anti-jam Feature

• Split Reporting of Selected Transmissions to Each Telephone Number

System Supervision Features

The PC5010 continuously monitors a number of possible trouble conditions including:
• AC Power Failure

• Trouble by Zone

• Fire Trouble

• Telephone Line Trouble

• Low Battery Condition

• Bell Output Trouble

• Loss of Internal Clock

• AUX Power Supply Fault

• Tamper by Zone

• Failure to Communicate

• Module Fault (Supervisory or Tamper)

System Introduction

Содержание Power832

Страница 1: ...04 module 1 PC5204 Output Fully Supervised for Siren Output Powerful 1 Amp Regulated Power Supply 500 mA Auxiliary Supply 12 VDC Positive Temperature Coefficient PTC components replace fuses Supervision for loss of AC Power Low Battery Internal Clock Locked to AC Power Frequency Power Requirements Transformer 16 5 VAC 40VA Battery 12 volt 4 Ah minimum rechargeable sealed lead acid Remote Keypad Sp...

Страница 2: ...fferent size systems 8 zone 16 zone and 32 zone PC5508 KP5508 PC5516 KP5516 PC5532 KP5532 LCD5500 KPL5500 8 zone LED keypad 16 zone LED keypad 32 zone LED keypad LCD keypad 1 2 2 PC5108 Eight Zone Expander Module Eight zone expander module can be used to increase the number of zones on the system Up to 3 modules can be connected to increase the system zones to a maximum of 32 See PC5108 Installati...

Страница 3: ... output is individually programmable with 14 different output options available See Section 5 10 PGM Outputs See PC5204 Installation Instructions Sheet 1 2 5 PC5208 Eight Low Current Output Module Adds eight low current outputs 50 mA to the control Each output is individu ally programmable with 14 different output options available See Section 5 10 PGM Outputs See PC5208 Installation Instructions ...

Страница 4: ...C5208 Eight Low Current Output Module Dimensions 153mm x 122mm x 38mm 6 x 4 8 x 1 5 approximately PC5001CP Plastic Cabinet to house the PC5108 Zone Expander Module and the PC5208 Eight Low Current Output Module Dimensions 146mm x 105mm x 25 5mm 5 75 x 4 2 x 1 approximately 1 2 11 Backplates There are two different backplates available for keypads to locate an Audio Station next to the keypad PC55B...

Страница 5: ...ing zones Step 6 Completing Wiring Complete all other wiring including bells or sirens phone line connections ground connections or any other wiring necessary Follow the guidelines provided in Section 2 2 Terminal Descriptions Step 7 Power up the Control Once all zone wiring and Keybus wiring is complete power up the control panel The panel will not power up if only the battery is connected Step 8...

Страница 6: ... prevent the panel from displaying a trouble condition See Section 3 4 Commands 2 Keybus Terminals RED BLK YEL GRN The Keybus is used by the panel to communicate with modules and by modules to communicate with the panel Each module has four Keybus terminals that must be connected to the four Keybus terminals on the panel For more information see Section 2 3 Keybus Operation and Wiring Programmable...

Страница 7: ...0 150 150 NOTE Module A is wired correctly as it is within 1 000 330m of the panel in wire distance Module B is wired correctly as it is within 1 000 330m of the panel in wire distance Module C is NOT wired correctly as it is further than 1 000 330m from the panel in wire distance 2 4 Current Ratings Modules and Accessories In order for the PC5010 system to operate properly the power output capabi...

Страница 8: ...or hardware operation OFF ON ON Zones not enabled for hardware operation ON OFF ON Zones 9 12 OFF OFF ON Zones 13 16 ON ON OFF Zones 17 20 OFF ON OFF Zones 21 24 ON OFF OFF Zones 25 28 OFF OFF OFF Zones 29 32 The following is a diagram of the zone expander PC5108 and locations of the jumper switches There are two sets of jumpers one set for the first 4 zones of the expander and one set for the oth...

Страница 9: ...r all modules on the system Once the search it will take about 1 minute is complete enter the following to confirm the modules on the system Step 3 Press 903 to display all modules Zone lights will be turned on according to what modules the panel has found on the system The LCD keypad will allow you to scroll through the modules Refer to the following chart Light 1 Keypad 1 present Light 13 Zones ...

Страница 10: ... 2 Single End Of Line EOL Resistors Wire all zones according to the following diagrams NORMALLY CLOSED CONTACT WITH 5600 Ω END OF LINE RESISTOR ANY Z TERMINAL ANY COM TERMINAL NORMALLY OPEN CONTACTS WITH 5600 Ω END OF LINE RESISTOR ANY Z TERMINAL ANY COM TERMINAL ANY Z TERMINAL ANY COM TERMINAL 2 NORMALLY OPEN CONTACT AND 2 NORMALLY CLOSED CONTACT WITH 5600 Ω END OF LINE RESISTOR 1 NORMALLY OPEN C...

Страница 11: ...s operate see Section 5 1 Zone Definitions 2 9 5 Fire Zone Wiring 2 wire Smoke Detectors If PGM2 has been programmed for 2 Wire Smoke Detector connection See Section 5 10 PGM Output the detectors must be wired according to the following diagram Ω For a complete description of how fire zones operate see Section 5 1 Zone Definitions If PGM2 is programmed for 2 wire smoke support Jumper J1 on the mai...

Страница 12: ...ing diagram Ω Ω 2 9 8 LINKS Answer Shall not be used on UL Listed systems If the LINKS1000 cellular communicator is being used a zone may be configured for LINKS Answer to allow downloading to be performed in the event of phone line failure When the LINKS receives a phone call it will activate the RING terminal on the LINKS circuit board This terminal can be used to violate a zone programmed as LI...

Страница 13: ...ogram the Partition Duress Code Partition Duress Codes By default Partition Duress Codes are not programmed They must be programmed by the System Master Code or the Partition Master Code for that Partition Once programmed if the Duress Code is used any time the panel will activate a silent Duress alarm See Section 5 7 Communicator Reporting Codes UserCodes By default the 32 User Codes are not prog...

Страница 14: ...s 1 Zone Bypass Other methods of Stay arming are available See Section 3 5 Function Keys 3 4 Commands 1 ZoneBypass ReactivateStay AwayZones The 1 keypad command can be used to bypass individual zones It can be used if the user wants to have access to an area while the Partition is armed or to bypass a defective zone bad contact damaged wiring until service can be provided A Partition can be armed ...

Страница 15: ...uffer will log a detailed description of the event Light 6 Not Used Light 7 PC5204 Low Battery The PC5204 module has a low backup battery Light 8 PC5204 AC Failure The PC5204 module has lost AC power Trouble 2 AC Failure This trouble indicates that AC power is no longer being supplied to the control unit If it is required to communicate this to a monitoring station program reporting codes in secti...

Страница 16: ...Access Code 40 Master Code Access Code 41 Partition 1 Master Code Access Code 42 Partition 2 Master Code All Access Codes have the ability to arm disarm any Partition s it is enabled for and activate the PGM Outputs using the 7 Access Code 1 and 7 2 commands SeeSection 3 4 Commands 7 Additional Access Code Attributes are also programmable Attributes determine what abilities the code will have The ...

Страница 17: ...ter all the codes and attributes have been programmed press the key to exit Access Code Programming How to erase Access Code Select the code to be erased and press 6 UserFunctions This keypad command can be used to program several different functions The following are the items programmable 1 Time and Date 2 Auto Arm Enable 3 Auto Arm Time 4 System Test 5 Enable DLS Downloading 6 Enable background...

Страница 18: ...ifferent keypad sounder tone options Use the arrow keys to scroll to the desired keypad beeper level and press the key to exit This function can be achieved on LED keypads by holding the key 7 Output Functions Two Output Functions can be performed at a keypad They are Utility Output and Smoke Detector Reset To activate Utility Output Press 7 1 Access Code The panel will activate all PGM Outputs fo...

Страница 19: ... beep means the feature has been disabled three short beeps means it has been enabled Reset Reset Smoke Detectors Pressing this key will cause the panel to activate for 5 seconds any output programmed as Sensor Reset In addition two wire smoke detectors connected to PGM2 will also be reset See Section 3 4 Commands 7 2 Exit Activate Quick Exit Pressing this key will cause the panel to activate the ...

Страница 20: ...rompt Help This feature can only be programmed if both the Escort5580 and the PC5928 Audio Matrix module are being used When the function key is pressed the intercoms will perform a Help page The user must then press the Page Answer button on any intercom station to begin the help session with the Escort For more information please refer to the PC5928 Installation Manual 16 0 Quick Exit Same as de...

Страница 21: ...e panel is waiting for the information to be programmed for the selected Section Enter the information written in the boxes for the Section found in the Programming Worksheets If a digit is entered for each program box in a Section the panel will automatically exit from the Section It will turn OFF the Ready light and turn the Armed light back ON You can also press the key to exit a Section before...

Страница 22: ... changes The panel will turn off the Ready light and turn on the Armed light 4 5 Viewing Programming 4 5 1 LED Keypads Any program Section can be viewed through the keypad When a Section is entered the keypad will immediately display the first digit of information programmed in that Section The keypad displays the information using a binary format where Zone Light 1 1 Zone Light 2 2 Zone Light 3 4...

Страница 23: ...Stay Mode See Section 3 5 Function Keys the panel is armed without entry delay See Section 3 4 Commands 9 the panel is armed and during the exit delay a Delay type zone is NOT tripped The automatic bypass avoids having the user manually bypass interior type zones when arming at home If automatically bypassed the user can reactivate the zones by entering the 1 command See Section 3 4 Commands 1 Zon...

Страница 24: ...ne Non medical emergency only 21 24 Hour Latching Tamper If this zone is violated the installer must enter Installer Programming before the panel will allow either Partition to be armed 22 Momentary Keyswitch Arm Zone Momentary violation of this zone will alternately arm disarm the Partition the zone is assigned to This zone type should not be programmed as global 23 Maintained Keyswitch Arm Zone ...

Страница 25: ...ator Reporting Code Communicator Call Direction Options are used to select which phone number the panel will dial when an event occurs If DTMF Dialing is enabled the panel will dial using DTMF touch tone If Switch to Pulse Dial is enabled the panel will switch to pulse dialing on the 5th attempt to call the central station If disabled the panel will always dial DTMF If DTMF Dialing is disabled the...

Страница 26: ...11 UL has only verified compatibility with the Sur Gard SG MLR2 DG 5 6 Communicator Reporting Formats Each central station phone number of the panel can be programmed to report using any one of the 4 formats available A 20 BPS pulse format is supported in addition to Contact ID SIA and a Pager format The following is a description of each 5 6 1 Pulse Formats Depending on the pulse format selected ...

Страница 27: ...f the reporting code for an event is programmed as anything from 01 to FF the panel will AUTOMATICALLY generate the zone or user code number 3 Bypassed zones will always be identified when partial closing the system The Communicator Call Direction Options can be used to disable reporting of events such as Openings Closings Also if all the Opening Closing reporting codes were programmed as 00 the p...

Страница 28: ...ition is armed with zones manually bypassed The code will also be transmitted if a Partition Auto Arms with zone s in violation A Special Closing Reporting Code will be transmitted if the Partition s is armed using any of the following methods Quick Arm Arming via the DLS Software Away Function Key arming Auto Arm Arming via keyswitch Stay Function Key arming Arming with the Maintenance Code A Clo...

Страница 29: ... will be transmitted as soon as the problem is corrected The Auxiliary Power Supply Trouble Alarm Reporting Code will be transmitted if the AUX output is shorted The AUX output control incorporates a fuseless design When excessive current is drawn the panel will automatically shut off the output The panel will constantly check the AUX output and when the excessive current draw is removed the panel...

Страница 30: ... the Downloading Answer option is enabled or during the first 6 hours after power up the panel will answer incoming calls for downloading provided the following conditions occur 1 The panel hears one or two rings then misses a ring 2 At this point the panel will start a timer 3 If the panel hears another ring before the Answering Machine Double Call Timer expires it will answer on the first ring o...

Страница 31: ...rtition 2 Zone Assignments Section 206 to 209 5 10 PGM Outputs There are 3 different types of Programmable Outputs available They are listed as follows PGM1 and PGM2 on the main board 8 low current outputs available with the PC5208 Output Module 4 high current outputs available with the PC5204 Power Supply Output Module Programming any of the PGM Outputs is a two step process First an option from ...

Страница 32: ...k 10 Latched System Event The PGM output will activate when any of the selected events occur It will deactivate when an access code is entered The normal PGM attributes programmed in Sections 141 to 154 is replaced with the following list for any output selected as Latched System Event Light 1 Burglary Delay Instant Interior Stay Away and 24 Hour Burglary Zones Light 2 Fire Fire Keys Fire Zone and...

Страница 33: ...d indicate a trouble condition if disconnected If TLM Enabled is selected the panel will wait the TLM Trouble Delay time before indicating the trouble so that a momentary interruption of the phone line will not cause a trouble condition The TLM Trouble Only or Audible When Armed option will allow you to select if the panel will indicate a trouble condition at the keypad or indicate a trouble at th...

Страница 34: ... is immediate If the Auxiliary Keys are pressed and held for 2 seconds the panel will sound the keypad beeper three times to verify activation The panel will beep the keypad ten times rapidly to verify communication to the central station If the Panic Keys are pressed and held for 2 seconds the panel will immediately communicate the signal to central station If Panic Keys Audible is enabled the pa...

Страница 35: ...it can be uploaded through the DLS software 5 16 1 Viewing the Event Buffer through the LCD Keypad The following is the procedure for viewing the event buffer through the LCD keypad Step 1 Enter 6 Master Code Step 2 Select View Event Buffer The keypad will display the Event Number Partition Time and Date of the event in question Use the key to toggle between this information and the event itself U...

Страница 36: ...f minutes Before the Auto Arm at a specific time function will work correctly the present Time of Day must be programmed When the internal panel clock matches the Auto Arm Time the panel will check the status of the Partition If armed the panel will do nothing until the next day at the Auto Arm Time when it will check again If disarmed the panel will sound the buzzer of all keypads assigned to the...

Страница 37: ...at least 500 milliseconds If Zone 8 is Fast Loop Response is enabled the loop response for zone 8 will be 40 milliseconds Typically this can be used for vibration type sensors Zone 8 is Fast Loop Response Section 013 Option 5 5 25 Keypad Tampers If the Keypad Tampers Enable option is selected the panel will display and transmit a General System Tamper reporting code if any keypad is removed from t...

Страница 38: ...the Zones 1 4 Enable Option is disabled zones 1 to 4 will be disabled for hardwire operation and wireless devices can be substituted Also if Zones 5 8 Enable Option is disabled zones 5 to 8 will be disabled for hardwire operation and wireless devices can be substituted After disabling or enabling main board zones the panel should be powered down Do not add wireless devices to the same zone as a ha...

Страница 39: ...te Printer The panel with the addition of the PC5400 printer module will print all events as they occur to a local on site serial printer All events printed will include the time date partition and the event If a problem develops with the printer such as power loss or paper outage the panel will store events until the problem is corrected at which point it will print the events from the buffer The...

Страница 40: ...Default Programming Section 996 Restore PC5400 to Factory Default Programming Section 997 Restore PC5928 to Factory Default Programming Section 998 5 32 Installer Lockout If Installer Lockout is selected a hardware default cannot be performed If a software default is performed all programming will restore to factory default When Installer Lockout Disable is selected the panel will restore all prog...

Страница 41: ...n fuse failure or improper operation Inspect wiring and ensure connections are correct before applying power Do not route any wiring over circuit boards Maintain at least 1 25 4mm distance Hookup Diagram P C 5 0 1 0 C O N T R O L P A N E L ...

Страница 42: ...ecksum bad 3 A5 System Reset 3 A6 Panel prog changed 3 A7 Self test failure 3 A8 System Shutdown 3 A9 Battery Test Failure 3 1A Ground Fault Sounder Relay Troubles 3 2A Sounder Relay 3 21 Bell 1 3 22 Bell 2 3 23 Alarm Relay 3 24 Trouble Relay 3 25 Reversing System Peripheral Troubles 3 3A System Peripheral 3 31 Polling Loop Open 3 32 Polling Loop Short 3 33 Exp Module Failure 3 34 Repeater Failure...

Страница 43: ...A XX BH XX Duress Alarm HA 00 Opening After Alarm OR 00 Recent Closing CR 00 Zone Expander Supervisory Alarm Restore UA 00 UH 00 Keypad Fire Alarm Restore FA 00 FH 00 Keypad Auxiliary Alarm Restore MA 00 MH 00 Keypad Panic Alarm Restore PA 00 PH 00 2 Wire Smoke Alarm Restore FA 99 FH 99 S I A V F O R M A T PC5010 Reporting Codes SIA Identifiers Auto Reporting Code Zone Tamper 1 32 TA XX Zone Tampe...

Страница 44: ...the protected area is to be under the responsibility of one ownership and management i e one business under one name This may be a group of buildings attached or unattached with different addresses but under the responsibility of someone having mutual interest The person of mutual interest is not the alarm installing company Bell Location The alarm sounding device bell must be located where it can...

Страница 45: ...e effectiveness of these features It is important that a security system be reviewed periodically to ensure that its features remain effective and that it be updated or replaced if it is found that it does not provide the protection expected Access by Intruders Intruders may enter through an unprotected access point circumvent a sensing device evade detection by moving through an area of insuffici...

Страница 46: ...uivalent in such a manner as to allow for easy immediate disconnection of the terminal equipment Standard jacks shall be so arranged that if the plug connected thereto is withdrawn no interference to the operation of the equipment at the customer s premises which remains connected to the telephone network shall occur by reason of such withdrawal INCIDENCE OF HARM Should terminal equipment or prote...

Страница 47: ... 2 DLS version 6 O or later W A R N I N G This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully read ...

Страница 48: ...tions 22 4 5 Viewing Programming 22 4 5 1 LED Keypads 22 4 5 2 LCD Keypad 22 Section 5 Program Descriptions 23 5 1 Zone Definitions 23 5 2 Zone Attributes 24 5 3 Communicator Dialing 25 5 4 Communicator Phone Numbers 25 5 5 Communicator Account Numbers 26 5 6 Communicator Reporting Formats 26 5 6 1 Pulse Formats 26 5 6 2 Contact ID 27 5 6 3 SIA Level 2 27 5 6 4 Pager Format 27 5 7 Communicator Rep...

Отзывы: