4

Wiring

NOTE:  Complete all wiring to the control panel before applying battery or AC power.

Burglary Zone Wiring

Burglary zone definition, (for example, Delay, Instant, 24-Hour, and so on) is programmed using the keypad.
Refer to Programming Guide Section [1].

Auxiliary Power Connection

The Auxiliary Power Supply can be used to power motion detectors and other devices that require 12 V

DC

.  The

total load for the Auxiliary Power Supply must be calculated for all devices connected across the AUX +/–
terminals and for devices connected between the AUX + and PGM terminals.  The output current cannot exceed
800 mA.

PGM Terminal Connections

The PGM terminal is a switched negative output which can be controlled by various programming options; refer
to Programming Guide Section [4].  Devices controlled by the PGM output must be connected between the PGM
terminal and the AUX+ terminal.

AC Power Wiring

Complete all wiring to the control panel before connecting AC power or the battery.  The transformer should
not be connected to an outlet that is controlled by a switch.

Battery Connection

If the battery is connected in reverse, the 5 A battery fuse will open and will need to be replaced.  The battery
charging voltage is factory set and normally needs no adjustment.

If AC power is OFF and the battery voltage drops to approximately 9.5 V or lower, the battery will be automatically
disconnected and the panel will power down.  To power up again, AC power will have to be re-established.  This
feature is designed to prevent damage to the battery due to prolonged discharging.

KEY Terminal Connection

The KEY terminal may be programmed for keyswitch operation or for use as a tamper zone.  Refer to the
Hook-up Diagram for instructions on wiring the KEY terminal.

Wire

Gauge

1900 / 579

3000 / 914

2400 / 1493

6200 / 1889

7800 / 2377

24

22

20

19

18

Maximum wire length to

End of Line Resistor

(feet/meters)

Figures are based on maximum wiring

resistance of 100 ohms.

Burglary Zone Wiring Chart

Z1

COM Z2

NC

NO

NC

NC

END OF LINE

RESISTOR

5600

0.5W

END OF LINE

RESISTOR

5600

0.5W

EOL RESISTOR

LOOPS USING

NO & NC

DEVICES

EOL RESISTOR

LOOPS USING

NC DEVICES

ONLY

Содержание PC51O

Страница 1: ...N G This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully rea...

Страница 2: ......

Страница 3: ...splay Trouble Conditions 6 3 Display Alarm Memory 6 4 Bell Test 6 5 Master Code Program Access Codes 7 6 Door Chime On Off 7 7 Utility Output Command 7 8 Installer s Code Installer s Programming Comma...

Страница 4: ...nes are End of Line Resistor supervised Maximum zone loop resistance 100 ohms Bell Siren Output fused for 5A Bell Siren Alarms steady and pulsed alarms Programmable Output 50 mA with 9 options Auxilia...

Страница 5: ...ontrol panel Disassemble the keypad by pressing gently on the locking tab found on the bottom of the unit With the tab disengaged pull the backplate from the keypad Prepare a hole in the wall at the d...

Страница 6: ...attery The transformer should not be connected to an outlet that is controlled by a switch Battery Connection If the battery is connected in reverse the 5 A battery fuse will open and will need to be...

Страница 7: ...med when the Ready light is ON To arm the system enter a 4 digit Access Code As each digit is entered the keypad sounder will beep When the Access Code has been entered the Armed light will come ON an...

Страница 8: ...zones will come ON Ensure that any zone displayed as being bypassed is intentionally bypassed Zone bypasses are automatically cancelled when the system is disarmed To Bypass Zones Enter 1 Access Code...

Страница 9: ...instructions on restoring the system s factory default programming 6 Door Chime On Off The Door Chime feature causes the keypad to beep whenever a Delay or Instant Zone is activated This feature is u...

Страница 10: ...for 2 seconds to generate a P Key alarm This alarm may be programmed as either silent or audible refer to Programming Section 5 When programmed as audible the keypad will sound a series of short beeps...

Страница 11: ...or programming For 2 digit numbers both digits must be programmed before pressing the Key Only the data entered before pressing the Key will be changed When all data for a section is completely entere...

Страница 12: ...zone will also have the standard Entry Delay provided that a Delay Zone has been activated before the Interior Zone If an Interior zone is tripped before a Delay zone an alarm will be generated 3 Home...

Страница 13: ...two 1 digit numbers in Section 4 The first number entered determines how the PGM1 terminal will operate the second number entered determines how the PGM2 terminal will operate Valid entries are from...

Страница 14: ...default settings Notes on P Key Operation If the P Key is programmed as a silent alarm it is suggested that one of the Programmable Outputs be programmed with Option 3 Option 4 or Option 8 so that an...

Страница 15: ...__________________________ Phone ________________________ Name ________________________________ Phone ________________________ ZONE INFORMATION Zone Type Protected Area 1 ____________________ ________...

Страница 16: ...ogrammable Output 1 7 activates PGM 2 Keypad sounder follow mode 3 Latched alarm 4 Steady Alarm P Key 5 24 Hour Pulsed Alarm F Key 6 PGM activates on A Key alarm 7 PGM activates on Trouble alarm 8 PGM...

Страница 17: ...Z1 COM Z2 NC NO NC NC END OF LINE RESISTOR 5600 0 5W END OF LINE RESISTOR 5600 0 5W EOL RESISTOR LOOPS USING NO NC DEVICES EOL RESISTOR LOOPS USING NC DEVICES ONLY TRANSFORMER 16VAC 20VA MIN DO NOT CO...

Страница 18: ...determined and which may be revised from time to time will be charged for each unit repaired Products which Digital Security Controls Ltd determines not to be repairable will be replaced by the neares...

Страница 19: ...not properly alert occupants of a fire for a number of reasons some of which follow The smoke detectors may have been improperly installed or positioned Smoke may not be able to reach the smoke detec...

Страница 20: ...1997 2002 Digital Security Controls Ltd Toronto Canada Printed in Canada 29000864 R1 1 800 387 3630...

Отзывы: