Disarming

Enter the premises through the designated Entry-Exit door.  The keypad will sound a tone to indicate that the
system must be disarmed.  Go to the keypad and enter an Access Code.  If an error is made entering the code,
press the [#] Key and enter the code again.  The “Armed” light will be shut OFF and the sounder will be silenced.
An Access Code must be entered before the Entry Delay expires or an alarm will sound.  To change the Entry
Delay, refer to Programming Section [2].

If an alarm occurred while the system was armed, the “System” light and the zone lights of the zones that went
into alarm will FLASH for two minutes.  Press the [#] Key to cancel the flashing display and to return the system
to the “Ready” mode.  Refer to [

][3]: Alarm Memory Display.

[

]+[0]:  Quick-Arm

The Quick-Arm feature allows a user to enter [

][0] to arm the system.  This command is designed to allow

someone to arm the system without that person having to be provided with an Access Code.  When [

][0] is

entered, the Exit Delay will begin and the user may exit the premises through the Entry/Exit door.  At the end
of the Exit Delay, the system will be fully armed.

[

]+[1]+[Access Code]:  Zone Bypassing

A bypassed zone will not cause an alarm.  Use zone bypassing when access is needed to part of a protected
area when the system is armed, or if damage to sensors or wiring cannot be repaired immediately.  The system
may be armed with one or more zones bypassed even if the zones are open.

With the system disarmed, enter [

][1][Access Code] to display the bypassed zones; the zone lights of

bypassed zones will come ON.  Ensure that any zone displayed as being bypassed is intentionally bypassed.
Zone bypasses are automatically cancelled when the system is disarmed.

To Bypass Zones:

Enter [

][1][Access Code]; the “System” light will FLASH.

Enter the number of the zone to be bypassed; the corresponding zone light will come ON to indicate that the
zone is bypassed.  To remove a bypass, enter the zone number and its zone light will be shut OFF.  When all
desired zones are bypassed, press the [#] Key to return to “Ready”.

[

]+[2]:  Display Trouble Conditions

The PC510 monitors two possible trouble conditions.  If an AC Failure occurs, the “System” light will come
ON.  If both the AC Failure and Battery Trouble are present, the “System” light will come ON and the keypad
sounder will sound two short beeps every 10 seconds.  To silence the sounder, press the [#] Key; the sounder
will be silenced but the “System” light will remain ON until the AC Failure trouble is cleared.

To display trouble conditions, enter [

][2].  Trouble conditions are represented with the zone lights; if a zone

light comes ON, then that trouble condition is present:

Zone Light

1

Battery Trouble. 

     If the battery voltage is low, a battery trouble will be displayed.  Note that the

Battery Trouble will only be indicated if AC power is off.

2

AC Failure. 

     If AC power is removed from the system, an AC trouble will be displayed.

[

]+[3]:  Display Alarm Memory

Alarms caused during the previous armed period are stored in memory.  To display the zones that went into
alarm, enter [

][3].  The “System” light will FLASH and the alarms will be displayed on the flashing zone lights.

The Alarm Memory will be cleared when the system is armed.

[

]+[4]:  Bell Test

Entering [

][4] will sound the siren and turn ON all the keypad lights for 2 seconds.

Содержание PC51O

Страница 1: ...N G This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully rea...

Страница 2: ......

Страница 3: ...splay Trouble Conditions 6 3 Display Alarm Memory 6 4 Bell Test 6 5 Master Code Program Access Codes 7 6 Door Chime On Off 7 7 Utility Output Command 7 8 Installer s Code Installer s Programming Comma...

Страница 4: ...nes are End of Line Resistor supervised Maximum zone loop resistance 100 ohms Bell Siren Output fused for 5A Bell Siren Alarms steady and pulsed alarms Programmable Output 50 mA with 9 options Auxilia...

Страница 5: ...ontrol panel Disassemble the keypad by pressing gently on the locking tab found on the bottom of the unit With the tab disengaged pull the backplate from the keypad Prepare a hole in the wall at the d...

Страница 6: ...attery The transformer should not be connected to an outlet that is controlled by a switch Battery Connection If the battery is connected in reverse the 5 A battery fuse will open and will need to be...

Страница 7: ...med when the Ready light is ON To arm the system enter a 4 digit Access Code As each digit is entered the keypad sounder will beep When the Access Code has been entered the Armed light will come ON an...

Страница 8: ...zones will come ON Ensure that any zone displayed as being bypassed is intentionally bypassed Zone bypasses are automatically cancelled when the system is disarmed To Bypass Zones Enter 1 Access Code...

Страница 9: ...instructions on restoring the system s factory default programming 6 Door Chime On Off The Door Chime feature causes the keypad to beep whenever a Delay or Instant Zone is activated This feature is u...

Страница 10: ...for 2 seconds to generate a P Key alarm This alarm may be programmed as either silent or audible refer to Programming Section 5 When programmed as audible the keypad will sound a series of short beeps...

Страница 11: ...or programming For 2 digit numbers both digits must be programmed before pressing the Key Only the data entered before pressing the Key will be changed When all data for a section is completely entere...

Страница 12: ...zone will also have the standard Entry Delay provided that a Delay Zone has been activated before the Interior Zone If an Interior zone is tripped before a Delay zone an alarm will be generated 3 Home...

Страница 13: ...two 1 digit numbers in Section 4 The first number entered determines how the PGM1 terminal will operate the second number entered determines how the PGM2 terminal will operate Valid entries are from...

Страница 14: ...default settings Notes on P Key Operation If the P Key is programmed as a silent alarm it is suggested that one of the Programmable Outputs be programmed with Option 3 Option 4 or Option 8 so that an...

Страница 15: ...__________________________ Phone ________________________ Name ________________________________ Phone ________________________ ZONE INFORMATION Zone Type Protected Area 1 ____________________ ________...

Страница 16: ...ogrammable Output 1 7 activates PGM 2 Keypad sounder follow mode 3 Latched alarm 4 Steady Alarm P Key 5 24 Hour Pulsed Alarm F Key 6 PGM activates on A Key alarm 7 PGM activates on Trouble alarm 8 PGM...

Страница 17: ...Z1 COM Z2 NC NO NC NC END OF LINE RESISTOR 5600 0 5W END OF LINE RESISTOR 5600 0 5W EOL RESISTOR LOOPS USING NO NC DEVICES EOL RESISTOR LOOPS USING NC DEVICES ONLY TRANSFORMER 16VAC 20VA MIN DO NOT CO...

Страница 18: ...determined and which may be revised from time to time will be charged for each unit repaired Products which Digital Security Controls Ltd determines not to be repairable will be replaced by the neares...

Страница 19: ...not properly alert occupants of a fire for a number of reasons some of which follow The smoke detectors may have been improperly installed or positioned Smoke may not be able to reach the smoke detec...

Страница 20: ...1997 2002 Digital Security Controls Ltd Toronto Canada Printed in Canada 29000864 R1 1 800 387 3630...

Отзывы: