G E T T I N G S T A R T E D
PC5015 Device Ratings (@ 12 V
DC
)
• LCD5500 Keypad: 50 mA
• PC5208 Output Module: 50 mA
• PC5532 Keypad: 45 mA
• PC5132 Wireless Module: 125 mA
• PC5516 Keypad: 45 mA
• Escort5580 Module: 150 mA
• PC5508 Keypad: 45 mA
• PC5928 Audio Interface Module: 65 mA
• LCD5500Z Keypad: 85 mA
• PC5921 Intercom Audio Station: 20 mA
• PC5532Z Keypad: 85 mA
• PC5921 EXT Door Box Audio Station: 20 mA
• PC5516Z Keypad: 85 mA
• PC5921 EXT/R Door Box Audio Station: 35 mA
• PC5508Z Keypad: 85 mA
• PC5400 Printer Module: 65 mA
• PC5108 Zone Module: 35 mA
• DLM-4L v1.0L: 180 mA
• PC5204 Output Module: 20 mA
• PC5700 Fire Module: 150 mA
• PC5108L Downlook Interface: 60 mA
Other Devices
Read the manufacturer’s literature carefully to determine the maximum current requirement (during
activation or alarm) and use this value for loading calculations. Do not allow connected devices to exceed
the system capabilities during any possible operational mode.
2.5
Assigning Zones to Zone Expanders
The main panel contains zones 1 to 8. Additional zone expanders may be added to increase the number
of zones on the system. Each zone expander consists of two groups of 4 zones and each group must be
configured to assign the specific zones to the expander. This is done by setting the jumpers located on
the expander to the proper settings.
Before a zone expander will work properly the jumpers must be set so the panel can determine the
correct zone assignment
.
The following are the jumper settings for different zone assignments:
Jumpers
System Zones Assigned
J1/J4
J2/J5
J3/J6
ON
ON
ON
Zones disabled
OFF
ON
ON
Zones disabled
ON
OFF
ON
Zones 09 - 12
OFF
OFF
ON
Zones 13 - 16
ON
ON
OFF
Zones 17 - 20
OFF
ON
OFF
Zones 21 - 24
ON
OFF
OFF
Zones 25 - 28
OFF
OFF
OFF
Zones 29 - 32
J1, J2 and J3 set system zone assignments for expander zones 1-4
J4, J5 and J6 set system zone assignments for expander zones 5-8
The following are diagrams of the PC5108 and PC5700 zone expander modules and where the jumper
switches are located. Refer to the Installation Instructions of each module for more information.
There are two sets of jumpers, one set for the first 4 zones of the expander and one set for the other 4 zones
.
In these two diagrams the jumpers settings shown indicate the first group of four zones of the expander
will be zones 9 to 12 and the second group of 4 zones will be 13 to 16. A group of zones can be disabled
if they are not required for the installation.