Utility Output Command: [
Q
]+[7]+[1 or 2]+[Access Code]
The PC2585 can control two utility outputs (PO1 and PO2) from the keypad. These outputs can be used for operating
other devices such as; garage door openers, special lighting or door strikes. The programmable outputs must be
selected for keypad utility using the [
Q
][8][Installer’s Code][31] command and programming a [1].
To enable PO1, enter [
Q
][7][1][Access Code]; to enable PO2, enter [
Q
][7][2][Access Code]. When the command is
entered, the keypad sounder and the programmable output are activated for 5 seconds.
Installer’s Programming Command: [
Q
]+[8]+[Installer’s Code]
The PC2585 is completely programmable from the keypad by using commands in the [
Q
][8] section. The commands
are described in detail in the Programming Section of this manual.
At-Home Arming: [
Q
]+[9]+[Access Code]
Entering [
Q
][9] before the arming code, arms the panel without any entry delay on the delay zones and bypasses zones
that are defined as “Home Away”. This command is used for arming the system while at home. When the panel is armed
using [
Q
][9], the “Armed” light will FLASH and the “Bypass” light will be ON to indicate that the “Home Away” zones
are bypassed. Once the panel is Armed in this mode, using [
Q
][1] will remove the bypass from those zones defined
as “Home Away” if they have not been manually bypassed. The [
Q
][1] command used here, only removes the bypass
from zones that have been Automatically bypassed with the [
Q
][9] command.
Quick-Arm Command: [
Q
]+[0]
Entering [
Q
][0] is accepted as a valid arming code when the “Quick-Arm” feature is activated. This command is often
used when individuals are only required to ARM the system. These individuals will not be able to disarm the system.
This could be used with home visitors in the case of a residential alarm or junior employees and maintenance staff in
the case of a commercial alarm. See instructions in the “[
Q
][6] User’s Function Commands” section for activating the
“Quick-Arm” feature. This feature should not be enabled if the One Time Use Code is enabled. The One Time Use Code
must be used for arming before it is erased.
Quick Exit Command: [
Q
]+[0] When Armed
Entering [
Q
][0] when the system is fully armed will allow the user 2 minutes to exit the premises through any delay zone
without altering the status of the system if the quick exit feature is enabled. The quick exit feature can be enabled by
turning ON Zone Light 7 in Section [23]. After [
Q
][0] is entered into an armed system, one and only one delay zone
may be tripped. Any additional activity on any other active zone will cause that zone to begin its alarm sequence.
[
Q
][0] for Quick Exit on a partially armed system is not supported.
Quick Exit must not be used when auxiliary delay zones are force armed. Turn Zone Light 4 in Section [24] OFF to
ensure proper operation.
Keypad Zones
IMPORTANT NOTE: While the Installer’s Programming Mode is active, the [F], [A] and [P] keys will be bypassed
until the Programming Mode is exited and an Access Code is entered.
There are three zones which can be activated from the keypad. The alarm and restoral codes for keypad zones are
programmed using the [
Q
][8] command.
Pressing the [F] key or the [1] and [3] keys for 2 seconds activates a fire alarm. The fire alarm sounds the siren/bell
in a pulsed mode and is annunciated as a memory condition. The Fire key can be turned OFF in Section [24].
Pressing the [A] key or the [4] and [6] keys for 2 seconds activates an auxiliary keypad zone. If a reporting attempt
is made to an alarm receiver and it is successful the PC2585 will acknowledge the transmission with a short series of
beeps from the keypad.
Pressing the [P] key or the [
Q
] and [#] keys for 2 seconds activates the Police (or Panic) alarm. The panic alarm can
be programmed for audible or silent operation (see Programming Section [24]).
There is no light annunciation from the keypad for the last two keypad zones, however, the keypad buzzer beeps 3
times to confirm activation on any of the keypad zones.
See Section [15] for alarm and restoral codes for all three keypad zones.
NOTE: Pressing two keys simultaneously to activate a keypad zone will only function with the PC2550RK
keypad. This function will not work on other keypad models.