Unsuccessful Communication:

     If the digital communicator is unsuccessful communicating with the monitoring

station after the maximum number of attempts to each telephone number that is to be tried, a trouble is generated.
If a later attempt to communicate is successful the trouble is cleared. This trouble can also be cleared by pressing
the [#] key to exit the trouble view mode. In Section [22] Zone Light 5, the trouble can be programmed to be audible
(bell will sound) or silent (bell will not sound)

6

Bell Circuit Failure:

     If the bell fuse is blown or the bell circuit is open, a keypad trouble and a trouble transmission

are generated.

7

Smoke Detector Zone Trouble:

 If a FIRE zone is open circuit, a keypad trouble and a trouble transmission are

generated. A trouble on the FIRE zone will unconditionally initiate an audible indication on the keypad. This means
that even if any other previous trouble has been silenced, a FIRE zone trouble will restart the keypad buzzer.

8

Loss of Internal Time:

     When the PC2585 is powered up or reset, the internal time of day clock needs to be set

to the correct time. This trouble is cleared when the trouble display is viewed and exited or when an attempt is made
to reset the internal time of day clock. See “[

Q

][6] User’s Function Commands” for resetting time of day clock.

If [9] is pressed while in the trouble display mode the most recent trouble will be displayed on the Zone Lights. This
trouble memory feature is useful as a diagnostic aid when installing and servicing the PC2585.

Alarm Memory Display: [

Q

]+[3]

Press [

Q

] then [3] to enter the alarm memory mode. The “Memory” light will FLASH and any alarm caused during the

last armed period will be displayed on the Zone Lights. In addition to the last alarm memory there are 2 history levels.
After entering the memory mode (pressing [

Q

] then [3]), pressing [9] will cause the keypad to display the two other

levels of alarm history. Each time [9] is pressed the keypad will beep 1, 2 or 3 times to indicate which level of history
is being viewed. When the panel is armed, the last alarm memory is cleared and the contents moves to the first history
level. The “Memory” light will only be ON when there was an alarm during the last armed period. Press [#] to return
to “Ready”.

Switched Auxiliary Supply Control: [

Q

]+[Hold Down 4]

To interrupt the switched auxiliary power supply press [

Q

] then hold down [4] for the desired interrupt time. When the

[4] is released the system returns to the ready mode and the switched auxiliary supply is restored.

User Programming Command: [

Q

]+[5]+[Master Code]

The [

Q

][5] user’s programming commands are used to program additional Access Codes. Up to 16 user arm-disarm

codes may be programmed. The first code is the Master Code (factory default [1234]). The 16th code is optionally a
“One Time Use”. The 16th code may be changed from a “One Time Use” code to a regular code using an installer’s
programming command (Section [23] Zone Light 6). Remember if no keypad entry is made for more than 2 minutes
the keypad will return to the normal arm-disarm display and the complete command will have to be re-entered to
program a new Access Code.

Programming Additional Access Codes

1

1

1

1

1

Press the [

Q

] and [5] keys then enter the Master code (default [1234]) to enter the additional code programming

mode. The “Program” light and Zone Light 1 will be ON to show that the first code (the Master Code) is already
programmed with the factory default code [1234]. The Master Code may be changed but do not try to erase the
Master Code. The installer can disable user changing of the Master Code by turning Zone Light 5 in Section [23]
ON.

2

2

2

2

2

Seven additional codes may be programmed. The Zone Lights are used to indicate which of these codes are
already programmed (zone ON steady) and the one which is currently being programmed (Zone Light is flashing).

3

3

3

3

3

To program the second code, press [2] and Zone Light 2 will FLASH. Then enter a 4 digit code and the buzzer will
beep three times and Zone Light 2 will come ON steady indicating a programmed code.

4

4

4

4

4

To remove the second code, press [2] - the buzzer will beep three times and Zone Light 2 will FLASH. Enter [

QQQQ

],

the buzzer will beep three times and Zone Light 2 will go out to show that the code has been removed.

5

5

5

5

5

Follow the instructions in 3 or 4 for programming or removing any of the other additional codes from 2 to 8.

6

6

6

6

6

To program Access Codes 9 to 16, press 9 to toggle into the upper code region. Zone Lights 1 to 8 now represent
Access Codes 9 to 16 (Zone Light 1 is code 9, Zone Light 8 is code 16). The ready and armed LED’s should flash
to indicate that the user is in the upper programming region. Program or remove Access Codes 9 to 16 as stated
in 3 and 4 above. Press 9 again to toggle back down to the lower region (Access Codes 1 to 8).

Содержание PC2585

Страница 1: ...This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully read So...

Страница 2: ...t a security system be reviewed periodically to ensure that its features remain effective and that it be updated or replaced if it is found that it does not provide the protection expected n n n n n A...

Страница 3: ...Master Code 1 12 Auto Arm Time of Day Q 6 Master Code 2 12 Auto Disarm Time of Day Q 6 Master Code 3 12 Quick Arm Q 6 Master Code 4 12 Auto Arm Enable Q 6 Master Code 5 12 Door Chime Q 6 Master Code...

Страница 4: ...ystem Option Code 27 27 Maximum Dialing Attempts per Buffer 27 28 Swinger Shutdown and Transmission Delay Bell Delay 28 29 Communications Format 28 30 Communicator Call Direction Options 31 31 PO1 PO2...

Страница 5: ...279 300 84 mm Weight 6 5 lbs 3 kg Remote Keypad Specifications PC2550RK Four wire QUAD hook up Nominal current draw 60 mA Upto3keypadspersystem recommended Maximum 5 keypads per system refer to Keypa...

Страница 6: ...pervision with LED625T or LCD600T keypads A loss of the AC power supply A supervised circuit trouble condition A telephone line monitoring circuit A bell circuit failure indicates open circuit or fuse...

Страница 7: ...E is a Tamper condition short Zone Connections for Bench Testing Connect the four keypad wires to the control panel as shown in the Hook up Diagram in the back of this manual To completely test the PC...

Страница 8: ...ect zone cables to zone inputs and put double end of line resistors on any unused zones Connect power wires for motion detectors to the auxiliary supply Install keypads and connect wires to keypad ter...

Страница 9: ...ypad for the AUX IN input An alarm on this input is created by applying a positive voltage or by closing a contact between the AUX IN terminal and the positive auxiliary supply See Programming Guide Q...

Страница 10: ...ypad is responding normally connect the battery The red battery lead attaches to the positive battery post and the black battery lead attaches to the negative battery post NOTE THE PC2585 WILL NOT STA...

Страница 11: ...ed for detailed installation instructions It is recommended that additional smoke detectors beyond those required be installed for increased protection The added areas include basement bedrooms dining...

Страница 12: ...Check to see if the Trouble or Bypass light is ON before arming the PC2585 Close all protected doors and windows and stop movement in areas covered by motion detectors Check to see that the Ready lig...

Страница 13: ...s every 10 seconds When the key is pressed the audible indication will stop but the Trouble light will remain ON until the trouble is cleared Trouble conditions can also be transmitted to the monitori...

Страница 14: ...nterrupt the switched auxiliary power supply press Q then hold down 4 for the desired interrupt time When the 4 is released the system returns to the ready mode and the switched auxiliary supply is re...

Страница 15: ...uick Arm enable disable 5 Auto Arm enable disable 6 Door Chime 7 Arm Disarm Memory 8 System Test 9 User Initiated Call up NOTE Enter the time in the 24 hour clock format Enter 00 to 23 for the hour an...

Страница 16: ...time To disable Auto Disarming program an invalid time such as 9999 Quick Arm Q 6 Master Code 4 The Quick Arm feature is enabled by pressing the 4 key while in the User s Function Commands section Wh...

Страница 17: ...Use Code is enabled The One Time Use Code must be used for arming before it is erased Quick Exit Command Q 0 When Armed Entering Q 0 when the system is fully armed will allow the user 2 minutes to ex...

Страница 18: ...0 Mannesman Tally MT81 with serial card 11 Raven 9101 with serial card Configuring the Printer 1 Serial interface 2 Baud rate 1200 other baud rates may be used but Section 49 must be changed according...

Страница 19: ...mally 31 Program with XX00 Program with XX00 32 to 48 Program normally Program normally 49 Printer setup Printer setup 50 Select Language Select Language 90 and 91 Program normally Program normally NO...

Страница 20: ...Code Section 47 Downloading Access Code A 4 digit code must be programmed into this section to allow access to the control panel by the downloading computer Section 48 Downloading Computer Telephone...

Страница 21: ...rmed light will come ON Enter the number of the next Section to be programmed It is not necessary to program all 2 digit numbers in a section After entering a section use the F key to skip to the desi...

Страница 22: ...rnate dialing only When alternate dialing is enabled the system will alternately call the First and Second TelephoneNumbersuntilcommunicationsarecompleted TheSecondTelephoneNumberisassignedtoCommunica...

Страница 23: ...ended Reporting Required 3 digit account code in Sections 02 04 or 06 i e enter 1230 for account code 123 Format code 06 07 08 09 10 depending on receiver type selected in Section 29 Two digit alarm r...

Страница 24: ...s follows C1 C2 C3 C4 C5 C6 C7 C8 Refer to Section 29 Communications Formats for more information The first digit HEX C is used to represent a closing signal this could be another number depending on...

Страница 25: ...ly fuse fails Downloading Lead in Downloading Lead out Refer to the Downloading section of this manual for information on the Downloading Lead in and Lead out codes Keypad Tamper Trouble Keypad Tamper...

Страница 26: ...9 2 Interior Zone is normally used with interior motion detectors and has the standard exit delay time The zone also has the standard entry delay time provided that a Delay Zone has been activated fir...

Страница 27: ...tion on a regular basis to confirm that the communication link to the system is intact The test transmission cycle time is how often in days the test transmission is sent This applies only if the Hour...

Страница 28: ...g the 9 key for about 3 seconds will make the system wait 60 minutes for computer to call Calls received after the 60 minute time will not be answered Default setting 22 Third System Option Code Refer...

Страница 29: ...Zone Light 7 OFF Quick exit disabled ON Quick exit enabled Zone Light 8 OFF Sensor Reset on Arming disabled ON Sensor Reset on Arming enabled When Zone Light 8 is ON the SW AUX output will reset for 5...

Страница 30: ...s disarmed ON 24Hr Bell Always on Tamper On a tamper condition the Bell will always sound Zone Light 6 OFF Tamper follows restore ON Installer Tamper reset If a tamper condition occurs then Installer...

Страница 31: ...led Section 25 Zone Light 3 OFF the system will arm without the 5 second delay for the Battery Test If the system is communicating when an Access Code is entered to arm the system the Battery Test wil...

Страница 32: ...es will not be delayed 29 Communications Format This Section sets the type of format in which Communication Buffers 1 and 2 will communicate For each communication buffer enter two digits from the lis...

Страница 33: ...the event with a particular item i e A reporting code of E3 means restore zone 3 E restore 3 zone 3 4 The following is a list of first digit identifiers that should be used with the Radionics format R...

Страница 34: ...d a beep on the line every 2 seconds after dialing the telephone number Although the event is not identified the recipient of the call is made aware of the alarm Private Line Format Do not use this fo...

Страница 35: ...e Auxiliary Input Zone PO1 can control the PC16OUT Module or any Programmable output option described below PO2 can control a Printer or any Programmable output option described below Programmable Opt...

Страница 36: ...nections section of this manual for details on the Auxiliary Input If a printer is attached to the panel 00 must be selected When option 03 is selected a momentary key closure between the Auxiliary In...

Страница 37: ...Codes Zone and Access Code assignments are programmed in Section 40 through 43 Typically zones and Access Codes are assigned to either Group A or Group B however the system may be programmed so that s...

Страница 38: ...s Before Answer and Downloading Configuration This section is used to enable the Downloading function If Downloading is enabled then the Downloading Access Code must be entered Section 47 and the Pane...

Страница 39: ...1 or 2 will be printed on the printer and communicated to the monitoring station If Zone Light 4 is ON All items whose reporting codes are programmed for Communications Buffer 1 or 2 will be printed...

Страница 40: ...s not entered correctly the keypad will sound a single long tone to indicate the error and the Installer s Lockout will not be disabled NOTE Control panels returned to DSC with the Installer Lockout f...

Страница 41: ..._______________________________________ 2 _____________________________ ________________________________________________________ 3 _____________________________ _______________________________________...

Страница 42: ...Page 18 For 3 digit Account Codes enter 0 for the last digit Where 0 zero is required in the Account Code enter HEX A Q 1 Q 03 Second Telephone Number Page 18 04 Second Account Code Page 18 05 Third...

Страница 43: ...ess Code 3 Closing Access Code 4 Closing Access Code 5 Closing Access Code 6 Closing Access Code 7 Closing Access Code 8 Closing Partial Closing Code 12 Closing Reporting Codes Access Codes 9 16 Page...

Страница 44: ...cess Code 12 Opening Access Code 13 Opening Access Code 14 Opening Access Code 15 Opening Access Code 16 Opening After Alarm Code 15 Priority Alarm and Restoral Reporting Codes Page 21 AUX Input Alarm...

Страница 45: ...r 3 Chime Silent 3 Home Away 4 24 hour Bell 5 24 hour Bell Buzzer 6 24 hour Buzzer 7 Auxiliary Delay 8 Interior Delay 19 System Times Page 23 Default 0 3 0 Entry Delay seconds 0 4 5 Exit Delay seconds...

Страница 46: ...wer Ack Tone 1300Hz ID Panel Answer Ack Tone 23 Fourth System Option Code Page 25 Default Zone Light ON Zone Light OFF OFF Zone Light 1 Send Identified Partial Closings Partial Closings not identified...

Страница 47: ...No keypad timeout OFF Zone Light 4 Keypad Tamper Enabled Keypad Tamper Disabled OFF Zone Light 5 Battery test every 10s Battery test every 4 minutes OFF Zone Light 6 AC Trouble Not Reported AC Troubl...

Страница 48: ...Restorals 1 Group A Access Codes Openings and Closings 1 Group B Access Codes Openings and Closings 1 Priority Alarms and Restorals 1 Maintenance Alarms and Restorals 31 PO1 PO2 and AUX IN Input Optio...

Страница 49: ...a Zone Light is ON that zone may be bypassed using the Q 1 Bypass command Default ON Zone 1 ON Zone 2 ON Zone 3 ON Zone 4 ON Zone 5 ON Zone 6 ON Zone 7 ON Zone 8 37 Access Code Bypass Mask Access Code...

Страница 50: ...ON Access Code 14 ON Access Code 15 ON Access Code 16 39 Keypad Lockout Options Page 33 Default 0 0 Number of attempts to enter a valid code before keypad locks out Enter 00 to disable this feature 1...

Страница 51: ...or OFF press its corresponding number key If the light is OFF when the key is pressed the light will come ON if the light is ON when the key is pressed the light will be shut OFF The default setting...

Страница 52: ...or Communications Buffer 2 will NOT be communicated to the monitoring station but will be printed on the printer If Zone Lights 4 and 5 are OFF All items whose reporting codes are programmed for Commu...

Страница 53: ...AWG 16 AWG 18 AWG 19 AWG 22 AWG 14 2750 838 1375 419 690 210 460 140 345 105 275 83 230 70 195 59 50 100 200 300 400 500 600 700 1740 530 870 265 435 132 290 88 215 65 170 52 140 43 125 38 1090 332 54...

Страница 54: ...L ANY COM TERMINAL ALARM CONTACT 5600 5600 DOUBLE EOL CIRCUIT 2 NORMALLY CLOSED CONTACTS WITH 5600 EOL RESISTORS ANY Z TERMINAL ANY COM TERMINAL ALARM CONTACT TAMPER CONTACT 5600 5600 NORMALLY CLOSED...

Страница 55: ......

Страница 56: ...1997 Digital Security Controls Ltd 1645 Flint Road Downsview Ontario Canada M3J 2J6 Tel 416 665 8460 Fax 416 665 9310 Printed in Canada 29002617 R0...

Страница 57: ...This manual contains information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer The entire manual should be carefully read So...

Страница 58: ...t a security system be reviewed periodically to ensure that its features remain effective and that it be updated or replaced if it is found that it does not provide the protection expected n n n n n A...

Страница 59: ...Master Code 1 12 Auto Arm Time of Day Q 6 Master Code 2 12 Auto Disarm Time of Day Q 6 Master Code 3 12 Quick Arm Q 6 Master Code 4 12 Auto Arm Enable Q 6 Master Code 5 12 Door Chime Q 6 Master Code...

Страница 60: ...ystem Option Code 27 27 Maximum Dialing Attempts per Buffer 27 28 Swinger Shutdown and Transmission Delay Bell Delay 28 29 Communications Format 28 30 Communicator Call Direction Options 31 31 PO1 PO2...

Отзывы: