20
Ethernet/Cellular Programming Options
3G Alarm Communicator Installation Manual
[037] Panel Firmware Update Fail
Default (FF);
Program 00 to disable this event transmission or FF to enable. This event will occur when the
panel firmware updated has failed.
Table 11: Panel Tamper Alarm Restore
Ethernet Receiver 1 Options
[101] Ethernet Receiver 1 Account Code
Default (0000000000)
The account code is used by the central station to distinguish between transmitters. This account
code is used when transmitting heartbeat signals to the central station receiver. Signals received
from the Panel will use the control panel account number. Valid range: 000000000
1
-
FFFFFFFFF
E
. Programming all
0
or all
F
will cause a Module Configuration Trouble.
NOTE:
If Ethernet Receiver 1 and Cellular Receiver 1 are programmed as the same receiver (IP
and port number are identical), Ethernet Receiver 1 account code will be used.
[102] Ethernet Receiver 1 DNIS
Default (000000)
The dialed Number Information Service (DNIS) is used in addition to the Account Code to iden-
tify the Communicator module at the central station. Valid range: 000000 -
0
99999. Value is
entered as a leading 0 followed by the 5 digit DNIS. Format is Binary Coded Decimal (BCD).
NOTE:
Each Ethernet/Cellular receiver must be programmed with a unique DNIS.
[103] Ethernet Receiver 1 Address
Default (127.000.000.001)
The default address enables the Communicator to operate in
Unattended Mode
.
Unattended Mode is used when a receiver is not available and the unit is required to perform DLS
sessions. Typically used where the customer programs the control panel daily due to access con-
trol and still wants to receive alarms without buying extra hardware (receiver) or software.
NOTE:
When a valid IP address has been programmed, Ethernet Receiver 1 is enabled and will
communicate events over the Ethernet channel.
Ethernet Receiver 1 and Cellular Receiver 1 may be configured to communicate to the same cen-
tral station receiver. To configure the device to operate using this Common Receiver Mode func-
tionality, program Ethernet Receiver 1 and Cellular Receiver 1, IP address and port number with
identical values.
NOTE:
When operating in Common Receiver Mode, Ethernet Receiver 1 account code will be
used for Ethernet and Cellular.
[104] Ethernet Receiver 1 Remote Port
Default (0BF5/3061)
This Section determines the remote port of Ethernet receiver 1. Valid range: 0000 - FFFF.
Event
SIA
Identifier
SIA
Reporting
Code
Contact
ID
Qualifier
Contact
ID
Event
Code
Contact
ID
Reporting
Code
Contact
ID
User/Zone
[033] Comm. FW Update Begin
LB
00
1
9
03
002
[034] Comm. FW Update Successful
LS
00
3
9
03
002
[035] Panel FW Update Begin
LB
00
1
9
03
003
[036] Panel FW Update Successful
LS
00
3
9
03
003
[037] Panel FW Update Fail
LU
00
1
9
04
003