23
Ethernet/Cellular Programming Options
3G Alarm Communicator Installation Manual
[205] Cellular Receiver 1 APN
Default ( )
The Access Point Name (APN) determines the Cellular network that the Communicator will con-
nect to. This information is available from your network carrier. Program this Section as 32 ASCII
characters.
NOTE:
When a SIM card with a custom APN is used, the unit will not have access to the Internet.
DLS and remote flash can still be done if Section [221] is programmed with a valid Public APN.
[206] Cellular Receiver 1 Domain Name
Default ( )
Enter the Domain Name as 32 ASCII characters. This information will be provided by your central
station system administrator.
Cellular Receiver 2 Options
[211] Cellular Receiver 2 Account Code
Default (0000000000)
The account code is used by the central station to distinguish between different transmitters. This
account code is used when transmitting signals to the central station receiver. Signals received on
the panel will use the panel account number. Valid range: 000000000
1
- FFFFFFFFF
E
.
NOTE:
Programming this Section as all 0 or F will cause a Module Configuration Trouble (yel-
low LED = 12 flashes).
[212] Cellular Receiver 2 DNIS
Default (000000)
The DNIS is used in addition to the Account Code to identify the Communicator module at the
central station. Valid range: 000000 -
0
99999. Values are entered as a 0 followed by the 5 digit
DNIS value. Format is BCD.
NOTE:
Each Ethernet/Cellular receiver must be programmed with a unique DNIS.
[213] Cellular Receiver 2 Address
Default (000.000.000.000)
Enter the Cellular Receiver 2 IP address. This IP address will be provided by your central station.
Format is 4 fields, each field is 3-digit decimal. Valid range: 000 - 255.
NOTE:
When a valid address has been entered, Cellular Receiver 2 is enabled and will communi-
cate events over the Cellular path.
[214] Cellular Receiver 2 Port
Default (0BF5/3061)
This Section defines the port of Cellular Receiver 2. Change the value of this port when your
installation is located behind a firewall and must be assigned a particular port number, as deter-
mined by your central station system administrator. Valid range: 0000 - FFFF.
NOTE:
Do not program Cellular Receiver 1 and Cellular Receiver 2 to communicate to the same
receiver.
[215] Cellular Receiver 2 APN
Default ( )
The APN determines the Cellular network that the Communicator will connect to. This informa-
tion is available from your network carrier. Program this Section with up to 32 ASCII characters.
NOTE:
When a SIM card with a custom APN is used, the unit will not have access to the internet.
DLS and remote flash can still be done if Section [221] is programmed with a valid Public APN.
[216] Cellular Receiver 2 Domain Name
Default ( )
Enter the Cellular Receiver 2 Domain Name with up to 32 ASCII characters.