12
7. Apply AC power to panel, and replace the panel cover.
NOTE: If two way audio is enabled you will NOT be able to swap the SIM card with
another card.
C
OMMUNICATOR
R
ESET
The Communicator can be reset by cycling the power on the SCW.
E
STABLISHING
A
C
OMMUNICATION
C
HANNEL
WITH
THE
SCW P
ANEL
.
The Communicator interfaces to the SCW through a keyed 16 pin Ribbon cable. See
Table 5 . The key prevents incorrect connection of the ribbon cable connector to the
SCW and Communicator. The pinout for the Ribbon cable is provided in the Table
below:
Establishing a communication channel between the Communicator and the SCW is
critical to ensuring the desired operation of the two units. The following steps must
be completed during the on-site installation. Program the following to ensure that the
Communicator and the panel will work together as intended.
Initial Programming of Communicator and SCW
1. Enter
[*][8][Installer Code] [Section Number]
for panel programming. Record any
values that are modified from their default, in the appropriate Programming
Worksheets.
NOTE: When programming Toggle Options, the toggle is ON when the number is
displayed and OFF when the number is not dis played. (e.g., [1 - - - 5 - - - ], Toggle
Options 1 and 5 are ON, all others are OFF).
2. Panel Section
[167]
Cellular/Ethernet Interface Communications ‘Wait for ACK’:
Default value is:
060
seconds.
3. When the communicator is installed with the SCW panel, 4 telephone numbers
are available to backup one another. You can set up these 4 telephone numbers to
perform in one of two ways: Backup dialling or Alternate dialling.
a.
Backup dialling
: each of the 4 telephone numbers will make 5 dialling attempts
in turn, before an FTC trouble is displayed on the keypad.
b.
Alternate dialling
: each telephone number makes 1 dialling attempt before
moving on to the next number, cycling through each of the 4 numbers for a total
of 5 times each. If all 4 numbers fail the 5 attempts, an FTC trouble is displayed
on the keypad.
4. Panel Sections
[301], [302], [303], and [305]
can be configured as Primary
communication paths.
a. Panel Sections
[302], [303],
and
[305]
may also be configured for backup or
redundant communications by using Panel Section(s)
[383]
or
[351] - [376]
.
Refer to the SCW panel Installation Manual for more information.
Table 5: Communicator Ribbon cable to SCW
Pin #
Signal
Pin #
Signal
1
PC-Link TX
2
PC-Link RX
3
GND
4
Vref
5
Vref
6
GND
7
AUD-OUT_N
8
AUD-OUT_P
9
AUD-IN_P
10
AUD-IN_N
11
GND
12
SI
13
GND
14
SO
15
GND
16
Wall Tamper