background image

HOT PRESS USERS MANUAL

11

FUNDAMENTALS OF DRYMOUNTING

Dry mounting an image to a substrate can be performed in a variety 

of ways and varies according to the nature of the mounting substrate, 

mounting  adhesive  and  the  print,  photo  or  artwork  being  mounted. 

However,  the  basic  methods  described  below  will  provide  excellent 

results for most standard applications. 

1. Set the vacuum press to reach an operating temperature of 

185°F (85°C)*.

2. Cut a piece of dry mounting tissue slightly larger (on all sides) 

than the work to be mounted.

3.  Place  your  print  face  down  onto  a  clean  work  surface  and 

cover with the dry mounting tissue. Lightly tack the tissue to the 

back  of  the  print  with  a  tacking  iron. To  avoid  adhesive  build-

up on the tacking iron, tack through silicone release paper/fi lm, 

shiny side toward the tissue. Trim the excess tissue.

4. Place the print, with the tissue attached, onto the mounting 

substrate.  Lift  the  opposite  end  of  the  print/mounting  tissue 

and  tack  the  mounting  tissue  side  directly  onto  the  mounting 

substrate.

5.  Place  the  three  components  into  the  press  between  two 

sheets  of  release  paper/fi lm  for  approximately  30  seconds  to 

3 minutes*– from the time the press has achieved the desired 

pressure setting.

* Your actual settings will vary according to the size of the press, type 

of  dry  mounting  tissue,  the  type  of  mounting  substrate,  the  artwork 

material  used  (in  terms  of  material  and  the  size  of  the  print).  See 

individual product specifi cations for recommended dwell times.

PROCESSING TIPS:

• Maximum vacuum pressure is 

recommended - except when 

mounting onto foam board, as this 

type of substrate may be subject 

to “crushing”. When mounting 

onto foam board, we recommend 

using reduced vacuum pressure 

during the mounting cycle. 

• We recommend silicone coated 

clear release fi lm over silicone 

release paper. Clear release fi lm 

is transparent (allowing you to 

see the work in progress), less 

prone to “creasing” and has a 

longer usage life.

• The diagram in Illustration 11A 

shows the positioning for each 

component in the dry mount 

package prior to being placed in 

the press.

Note:

 Clear release fi lm or silicone release paper must be placed on 

top of the “mounting package” to prevent any exposed adhesive from 

sticking to the glass.

Mounting

Illustration 11B:

 Tacking dry 

mounting components

Illustration 11A:

 Top to bottom material 

placement order in press

Содержание HOT PRESS HGP220

Страница 1: ...M PRESS USERS MANUAL This users manual applies to the following Hot Press models HGP220 25 x 37 635mm x 940mm HGP260 35 x 47 890mm x 1194mm HGP360 42 5 x 66 5 1080mm x 1689mm HGP560 50 25 x 98 25 1276mm x 2496mm Model Working Area Revised 7 30 05 ...

Страница 2: ...an be viewed throughout most bonding processes The glass is extremely smooth and scratch resistant The Hot Press Glass Top Press handles a wide range of presentation materials from foam board and wood to photos art prints and delicate fabrics The Hot Press brand is well regarded by picture framers and other finishing professionals for its ability to produce consistent high quality results All model...

Страница 3: ...talled in a location which allows the lid to be completely raised without interference If the lid is only partially opened it may close unexpectedly Before each use the struts should be checked to be sure they are operating properly Over a period of time the struts will lose pressure and will eventually require replacement The inner surface of the glass top is very hot during normal operation Be v...

Страница 4: ...f the unit Unpack and remove the vacuum pump from its box The pump should be placed on or near the floor There are suction cups on the bottom of the pump to help keep it in place since the pump vibrates during operation The pump will become warm during extended usage If the equipment is going to be used in a high volume production environment please allow for adequate ventilation of the area where ...

Страница 5: ... x 60 mm bolts Loosely fit the bottom rails about half way up the leg assemblies using the remaining M8 x 60 bolts Tighten all bolts using the Allen key and ensure stand is steady The top rails are inset from the front and rear the largest inset is the front of the stand Lift press onto stand Fit M6 x 80 mm bolts with shakeprooof washers then with the penny washers then insert them up through the l...

Страница 6: ...oes not present a hazard Protect the cord at all times from sharp objects hot surfaces oil and chemicals Avoid kinking the cord Periodically inspect the cord and plug and replace immediately if worn or damaged Disconnect the equipment from the power source before moving or servicing Test the GFCI Ground Fault Circuit Interrupter circuit breaker It is the circuit breaker located nearest to the cent...

Страница 7: ...nel is in the AUTO position and Manual that the power switch is in the OFF position Connect the power cord to the electrical outlet Remove any materials from inside the press then close and latch the lid Turn the Pressure Adjustment Knob fully clockwise maximum vacuum Turn on the power switch on the front of the press The displays on the Timer and Timer and Timer Temperature controllers should lig...

Страница 8: ... 239 F The factory preset temperature is 194 F ADJUSTING THE TEMPERATURE CONTROLLER CELSIUS To adjust the preset temperature press Button 1 and L1 will appear for one second Then press Button 3 to increase or Button 3 to increase or Button 3 Button 4 to decrease the preset temperature Once the desired level is reached press Button 1 to set your required temperature When current is flowing through t...

Страница 9: ... press Button 3 to start the Button 3 to start the Button 3 cycle The timer will indicate that the pump is on and begin to count down Once the preset time has elapsed the pump will stop the vacuum will be released and the counter will return to showing the preset time If you wish to stop the cycle part way through simply press Button 4 This will stop the pump release the vacuum and reset the timer...

Страница 10: ...well This factor works in conjunction with temperature to create a permanent bond between materials Assuming that the temperature setting of the press is sufficient to activate the adhesive it is almost always preferable to increase dwell rather than temperature Dwell time is set using the Timer page 9 and dictates the vacuum cycle see Pressure below Pressure Pressure is established in the press by...

Страница 11: ...etween two sheets of release paper film for approximately 30 seconds to 3 minutes from the time the press has achieved the desired pressure setting Your actual settings will vary according to the size of the press type of dry mounting tissue the type of mounting substrate the artwork material used in terms of material and the size of the print See individual product specifications for recommended dw...

Страница 12: ...aminate on top exposed adhesive edge down While holding it firmly on the table with one hand gently pull the release paper away and toward you from underneath 4 Check that there is no dirt or dust trapped under the laminating film If necessary the film may be gently lifted the contaminants removed and the film repositioned 5 Using a burnishing pad or soft cloth lightly smooth the laminating film down o...

Страница 13: ...uld simply be wiped with a TacCloth to remove dust particles MAT BOARDS MILL BOARDS To prepare mat board or millboard for mounting use the Anti Static Wisk brush to remove dust particles and other debris HARDBOARD E G MEDIUM DENSITY FIBERBOARD MASONITE ETC To prepare hardboard substrates for mounting wipe down the surface with a TacCloth Should the surface contain irregularities use sandpaper to r...

Страница 14: ...ing threaded shaft Adjust only one turn at a time Lengthening the amount of threaded shaft visible by turning counterclockwise will tighten the latch and shortening the amount by turning clockwise will loosen it Overtightening the latches will not improve the effectiveness of the vacuum seal and will cause the latches to wear out prematurely Hinge Adjustment The hinges at the rear of the press are...

Страница 15: ...e press Refer to the Routine Maintenance section on page 14 for the procedure A gap at the front of the press may also indicate that the latches need to be adjusted The latches should snap shut with a firm click but should not be difficult to close If they are too loose follow the adjustment procedure in the maintenance section Do not overtighten the latches as this will cause them to wear out prema...

Страница 16: ... is not check the circuit breaker at the building s electrical distribution panel Unplug the power cord and check the fuses on the left side of the unit 2 Press starts up normally then overheats and shuts off or the temperature controller displays an error code such as PFA or LOR There is a problem with the temperature controller or temperature sensor Contact Drytac for assistance with repairs 3 V...

Страница 17: ...x 98 25 in 1276mm x 2496mm Time to Vacuum HGP220 HGP260 20 seconds typical HGP360 HGP560 30 seconds typical Time to Temperature HGP220 HGP260 HGP360 12 minutes typical HGP560 15 minutes typical Voltage All Models 220 240VAC Single Phase 50 60Hz Power Consumption maximum HGP220 2 3 kW HGP260 2 5 kW HGP360 4 2 kW HGP560 5 75 kW Current nominal maximum HGP220 10 11 Amps HGP260 11 13 Amps HGP360 18 22...

Страница 18: ...Pump for HGP220 PUMP260 Vacuum Pump for HGP260 PUMP360 Vacuum Pump for HGP360 PUMP560 Vacuum Pump for HGP560 REPLACEMENT PARTS XDIAP HGP220 HGP220 Diaphragm XDIAP HGP260 HGP260 Diaphragm XDIAP HGP360 HGP360 Diaphragm XDIAP HGP560 HGP560 Diaphragm Conduit Bushing Conduit Pipe XFUSE 1A Fuse 1 Amp 20mm XFUSE 5A Fuse 5 Amp 20mm XMCB 260 MCB Double Pole 16amp XMCB 360 MCB Double Pole 20amp XMCB 560 MCB...

Страница 19: ...period has elapsed Drytac will provide all reasonable assistance and will maintain stock of replacement parts This will ensure that any problems that arise can be resolved quickly and economically Please feel free to contact Drytac if you have any questions or problems When calling please have the following information ready Press Model Serial Number found on plate on left side of press Date of Pu...

Отзывы: