![Dryer Master DM510 Скачать руководство пользователя страница 20](http://html.mh-extra.com/html/dryer-master/dm510/dm510_user-manual_2533264020.webp)
Page | 19
Dryer Master DM510
Operations Manual
and sound can be cleared with the push of the ‘CANCEL’ key but the status light will remain
illuminated until the condition is corrected
e)
Grain
Temp
.: Alarm for both the inlet and outlet product temperature. The status light
will illuminate RED when the high or low product temperature is exceeded for either the
inlet or the outlet product temperature or there is a fault. A descriptive message explaining
the alarm will also be displayed on the main screen along with an alarm sound. The
message and
sound can be cleared with the push of the ‘CANCEL’ key but the status light will
remain illuminated until the condition is corrected
2. Mode:
a)
Auto
: The Auto status light is illuminated when the DM510 is controlling the dryer
automatically.
b)
Ready
: The Ready status light is illuminated when the DM510 system has gathered
sufficient information to be placed into Automatic mode when this status light is lit, the
operator can select Automatic Mode. The supervisor can also select Auto Fast Start. When
aut
o fast start is enabled the operator can select ‘Automatic Mode’ as soon as the learn
status light is lit. Great care must be used with this feature, as the DM510 Dryer Master may
not have sufficient information to set the correct discharge or unload rate.
c)
Learn
: The Learn status light is illuminated when the dryer is operating and the moisture
sensors have product.
d)
Remote
: The Remote Status light is illuminated when the DM510 system is in control of
the dryer
’
s discharge system either manually or automatically. When this status light is NOT
illuminated dryer control is from the dryer panel.