background image

 

 

7.2 USE 

 

Check the setting data indicated on the control panel (if present); 

 

Press the start button on the machine where the pump is connected; 

 

Ensure that the pump starts; 

 

Ensure the adequate lubrication of the machine (if there are doubts on correct operation, you can contact the Dropsa 
S.p.A. Technical Office and ask for the testing procedure). 

 

 

7.3 FILLING THE RESERVOIR 

Check that all the pump housing holes/caps are occupied. 
Filling the reservoir is carried out by means of the fully dedicated filter devices. Proceed with filling, ensuring not to exceed 
the maximum level line. If this happens, you will note a spill of lubricant from the underside of the lid, which acts as an air 
vent. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

 
7.4 HOW TO USE 

If there are no regulations foreseen, the pump is electrically powered by a system that controls the drive and that handles 
the minimum level contact. For the operation of the lubrication system, refer to the machine’s management and control 
instructions where the pump is installed. 
 
 
 
 
 
 
 
 
 
 
 
 
 

ATTENTION

:

 To avoid any malfunctions and to prevent the warranty from becoming void, we recommend 

filling the lubricant without impurities, exclusively from dedicated loading system. 
Please refer to Section 14.2 Lubricants for the lubricant specifications to be used. 

 

Loading with cartridge 

(Part Number 888038) 

Loading grease 

nipple 

Содержание PoliPUMP eco

Страница 1: ...ng and Maintenance Manual Original Instructions Manual drawn up in accordance with EC Directive 06 42 C2291IE WK 24 19 Dropsa products can be purchased from Dropsa bracnhes and authorized distributors...

Страница 2: ...UNPACKING 6 6 2 INSTALLATION OF PUMPING ELEMENTS CAPS 6 7 OPERATING INSTRUCTIONS 8 7 1 MEASURES TO BE TAKEN PRIOR TO START UP 8 7 2 USE 9 7 3 FILLING THE RESERVOIR 9 8 PROBLEMS AND SOLUTIONS 10 9 MAIN...

Страница 3: ...ions and in various types of machinery for use with grease Any use other than the use intended shall be deemed to be in non compliance with requirements 2 2 SPECIFICATIONS The PoliPUMP eco electric pu...

Страница 4: ...pumping element 80bar 1 160psi Reservoir capacity 2 litres 0 53 gallons Grease consistency NLGI00 NLGI2 Protection degree IP 69 Temperature of use 10 C 60 C 14 F 140 F Storage temperature 20 C 80 C 4...

Страница 5: ...GREY 5 notches 0 10cc cycle BLACK 6 notches 0 13cc cycle Push in outlet 4 Notches Pump replacement cap included within the scope of supply Stirring paddle with wiper reservoir Input power cable gland...

Страница 6: ...ition by distributing them evenly over the holes on the pumping element holder cylinder No MOUNTING POSITIONS No MOUNTING POSITIONS No MOUNTING POSITIONS 1 1 13 13 25 25 2 1 7 14 13 19 26 25 31 3 1 5...

Страница 7: ...e pipes and wires have been properly fastened and protected from any possible impact Verify that the grease used is fit for operating temperatures especially at temperatures below 0 C If in doubt cont...

Страница 8: ...temperature and that the pipelines are free of any air bubbles Check the correct connection of electrical devices To determine the maximum operating pressure it is necessary to know the pressure drop...

Страница 9: ...the maximum level line If this happens you will note a spill of lubricant from the underside of the lid which acts as an air vent 7 4 HOW TO USE If there are no regulations foreseen the pump is electr...

Страница 10: ...e time The pump begins the greasing phase but ends it immediately Defective motor or high output absorption Allow to cool for a few minutes and try again If the problem persists replace the gear motor...

Страница 11: ...s the periodic inspections the frequency and the intervention that the maintenance will have to carry out in order to ensure the efficiency of the system over time CHECK FREQUENCY INTERVENTION Attachm...

Страница 12: ...888274 ECO 0888275 ECO 0 04cc cy cle 0888453 0 13cc cycle 0888456 OPTIONAL SPARE PARTS PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION 5717300 Nylon tube 4x3 low pressure 0888257 Pump replacement cap...

Страница 13: ...ND TRANSPORT Before shipment the pumps are carefully packed inside a cardboard box During transport and storage of the equipment pay attention to the direction indicated on the box Upon receipt check...

Страница 14: ...ISO 12100 Electrical safety requirements EN 60204 1 The hazards that have not been entirely eliminated but that have been deemed acceptable are listed below During the maintenance phase low pressure s...