background image

 

 

 

4. TECHNICAL CHARACTERISTICS 

 

GENERAL TECHNICAL CHARACTERISTICS 

Pumping system 

With single acting pumping systems with cam 
drive 

Drive assembly 

DC motor with reducer  

Motor power-supply voltage 

12V DC 

24V DC 

Net weight 

standard version 

3 Kg (6.6 lb) 

Max. number of outlets/pumping elements 

12 – 24 – 36 

Delivery connection (pumping element outlet) 

Push-in Ø4mm (5/32in) 

Nominal flow rate for single pumping element * 

0.02cc/stroke 

– RED    

(1 notch) 

0.03 cc/stroke 

– GREEN  

(2 notches) 

0.04 cc/stroke 

– YELLOW 

(3 notches) 

0.08 cc/stroke 

– BLUE   

(4 notches) 

0.10 cc/stroke 

– GREY                  (5 notches) 

0.13 cc/stroke 

– BLACK  

(6 notches) 

Rotation speed (cycle) 

3 RPM 

Maximum reachable pressure 
on the outlet of the pumping element 

80bar** (1,160psi) 

Reservoir capacity  

 

2 litres (0.53 gallons) 

Grease consistency  

NLGI00 ÷ NLGI2 

Protection degree 

IP 69 

Temperature of use 

-10°C ÷ +60°C (14°F ÷ 140°F) 

Storage temperature 

-20°C ÷ +80°C (-4°F ÷ 176°F) 

Max. relative humidity without operating condensation 

90% 

Sound pressure level 

< 70 db (A) 

Electrical connection terminal 

1.5mm² max. 

 

 

 

 

 
 
 
 
 
 
 
 
 

ATTENTION

:

 Do not power the machine with voltage different than what is indicated on the label. 

 

* NOTE: 

The  flow  rate  indicated  refers  to  the  following  test  conditions:  grease  with  NLGI  class  00;  ambient 
temperature 20° C (68° F); ambient pressure 1 bar (14.5 psi); back pressure of 5 bar (72.5 psi). 
 
** NOTE: 
The  date  refers  to  the  maximum  operating  pressure  of  the  single  pumping  element.  The  maximum 
pressure supplied by the pump depends on several variables (number of pumping elements used, type 
of grease, operating temperature, see Section 7).

 

 

Содержание PoliPUMP eco

Страница 1: ...ng and Maintenance Manual Original Instructions Manual drawn up in accordance with EC Directive 06 42 C2291IE WK 24 19 Dropsa products can be purchased from Dropsa bracnhes and authorized distributors...

Страница 2: ...UNPACKING 6 6 2 INSTALLATION OF PUMPING ELEMENTS CAPS 6 7 OPERATING INSTRUCTIONS 8 7 1 MEASURES TO BE TAKEN PRIOR TO START UP 8 7 2 USE 9 7 3 FILLING THE RESERVOIR 9 8 PROBLEMS AND SOLUTIONS 10 9 MAIN...

Страница 3: ...ions and in various types of machinery for use with grease Any use other than the use intended shall be deemed to be in non compliance with requirements 2 2 SPECIFICATIONS The PoliPUMP eco electric pu...

Страница 4: ...pumping element 80bar 1 160psi Reservoir capacity 2 litres 0 53 gallons Grease consistency NLGI00 NLGI2 Protection degree IP 69 Temperature of use 10 C 60 C 14 F 140 F Storage temperature 20 C 80 C 4...

Страница 5: ...GREY 5 notches 0 10cc cycle BLACK 6 notches 0 13cc cycle Push in outlet 4 Notches Pump replacement cap included within the scope of supply Stirring paddle with wiper reservoir Input power cable gland...

Страница 6: ...ition by distributing them evenly over the holes on the pumping element holder cylinder No MOUNTING POSITIONS No MOUNTING POSITIONS No MOUNTING POSITIONS 1 1 13 13 25 25 2 1 7 14 13 19 26 25 31 3 1 5...

Страница 7: ...e pipes and wires have been properly fastened and protected from any possible impact Verify that the grease used is fit for operating temperatures especially at temperatures below 0 C If in doubt cont...

Страница 8: ...temperature and that the pipelines are free of any air bubbles Check the correct connection of electrical devices To determine the maximum operating pressure it is necessary to know the pressure drop...

Страница 9: ...the maximum level line If this happens you will note a spill of lubricant from the underside of the lid which acts as an air vent 7 4 HOW TO USE If there are no regulations foreseen the pump is electr...

Страница 10: ...e time The pump begins the greasing phase but ends it immediately Defective motor or high output absorption Allow to cool for a few minutes and try again If the problem persists replace the gear motor...

Страница 11: ...s the periodic inspections the frequency and the intervention that the maintenance will have to carry out in order to ensure the efficiency of the system over time CHECK FREQUENCY INTERVENTION Attachm...

Страница 12: ...888274 ECO 0888275 ECO 0 04cc cy cle 0888453 0 13cc cycle 0888456 OPTIONAL SPARE PARTS PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION 5717300 Nylon tube 4x3 low pressure 0888257 Pump replacement cap...

Страница 13: ...ND TRANSPORT Before shipment the pumps are carefully packed inside a cardboard box During transport and storage of the equipment pay attention to the direction indicated on the box Upon receipt check...

Страница 14: ...ISO 12100 Electrical safety requirements EN 60204 1 The hazards that have not been entirely eliminated but that have been deemed acceptable are listed below During the maintenance phase low pressure s...

Отзывы: