background image

 

12 

 

 

11. ORDER INFORMATION 

 

PUMPS

 

PUMPING ELEMENTS

 

Power 
zione 

Max. number of PUMPING ELEMENTS 

CAPACITY  PART 

NUMBER 

CAPACITY 

PART 
NUMBER 

12 

24 

36 

0.02cc/cy

cle 

0888451 

0.08cc/cycle  0888454 

12VDC 

0888270-ECO 

0888271-ECO  0888272-ECO 

0.03cc/cy

cle 

0888452 

0.10cc/cycle  0888455 

24VDC 

0888273-ECO 

0888274-ECO  0888275-ECO 

0.04cc/cy

cle 

0888453 

0.13cc/cycle  0888456 

OPTIONAL 

SPARE PARTS 

PART 

NUMBER 

DESCRIPTION 

PART 

NUMBER 

DESCRIPTION 

5717300 

Nylon tube Ø4x3 (low pressure) 

0888257 

Pump replacement cap 

5717218 

Nylon tube, Ø4x2, white, 100m 

0888116 

Reservoir (standard) 

5717258 

Nylon tube, Ø4x2, black, 25m 

3130022 

Filling filter 

5717259 

Nylon tube, Ø4x2, black, 25m, loaded NLGI 00 

 

0888038 

Grease filling cartridge kit 

3133723 

Valved grease filling cartridge kit 

3077222 

Fitting for loading at 90° M22x1.5 

Содержание PoliPUMP eco

Страница 1: ...ng and Maintenance Manual Original Instructions Manual drawn up in accordance with EC Directive 06 42 C2291IE WK 24 19 Dropsa products can be purchased from Dropsa bracnhes and authorized distributors...

Страница 2: ...UNPACKING 6 6 2 INSTALLATION OF PUMPING ELEMENTS CAPS 6 7 OPERATING INSTRUCTIONS 8 7 1 MEASURES TO BE TAKEN PRIOR TO START UP 8 7 2 USE 9 7 3 FILLING THE RESERVOIR 9 8 PROBLEMS AND SOLUTIONS 10 9 MAIN...

Страница 3: ...ions and in various types of machinery for use with grease Any use other than the use intended shall be deemed to be in non compliance with requirements 2 2 SPECIFICATIONS The PoliPUMP eco electric pu...

Страница 4: ...pumping element 80bar 1 160psi Reservoir capacity 2 litres 0 53 gallons Grease consistency NLGI00 NLGI2 Protection degree IP 69 Temperature of use 10 C 60 C 14 F 140 F Storage temperature 20 C 80 C 4...

Страница 5: ...GREY 5 notches 0 10cc cycle BLACK 6 notches 0 13cc cycle Push in outlet 4 Notches Pump replacement cap included within the scope of supply Stirring paddle with wiper reservoir Input power cable gland...

Страница 6: ...ition by distributing them evenly over the holes on the pumping element holder cylinder No MOUNTING POSITIONS No MOUNTING POSITIONS No MOUNTING POSITIONS 1 1 13 13 25 25 2 1 7 14 13 19 26 25 31 3 1 5...

Страница 7: ...e pipes and wires have been properly fastened and protected from any possible impact Verify that the grease used is fit for operating temperatures especially at temperatures below 0 C If in doubt cont...

Страница 8: ...temperature and that the pipelines are free of any air bubbles Check the correct connection of electrical devices To determine the maximum operating pressure it is necessary to know the pressure drop...

Страница 9: ...the maximum level line If this happens you will note a spill of lubricant from the underside of the lid which acts as an air vent 7 4 HOW TO USE If there are no regulations foreseen the pump is electr...

Страница 10: ...e time The pump begins the greasing phase but ends it immediately Defective motor or high output absorption Allow to cool for a few minutes and try again If the problem persists replace the gear motor...

Страница 11: ...s the periodic inspections the frequency and the intervention that the maintenance will have to carry out in order to ensure the efficiency of the system over time CHECK FREQUENCY INTERVENTION Attachm...

Страница 12: ...888274 ECO 0888275 ECO 0 04cc cy cle 0888453 0 13cc cycle 0888456 OPTIONAL SPARE PARTS PART NUMBER DESCRIPTION PART NUMBER DESCRIPTION 5717300 Nylon tube 4x3 low pressure 0888257 Pump replacement cap...

Страница 13: ...ND TRANSPORT Before shipment the pumps are carefully packed inside a cardboard box During transport and storage of the equipment pay attention to the direction indicated on the box Upon receipt check...

Страница 14: ...ISO 12100 Electrical safety requirements EN 60204 1 The hazards that have not been entirely eliminated but that have been deemed acceptable are listed below During the maintenance phase low pressure s...

Отзывы: