Three
savvyPanel
Tile Types
Parameter Tiles
. Touch a settable parameter to
see its
savvyPanel
setter. Includes; slider,
keypad, 1x, 10x increment, default & revert.
A parameter is settable if it is not read-only and
has no incoming
drive.web
connection.
Meter
tiles; digital panel meter, dial or bar
meter. Unipolar or bipolar. Full-scale or percentage.
Indicator
tiles. Variety of colors. Shows on/off, true/false state.
Pushbutton
tiles; colored momentary and lighted Start/Stop.
Multi-position Switch
tiles for enumerated parameters.
Graphic Tiles
- create diagrams with a variety of process elements.
Page-Link Tiles
- A graphic tile that is also a touch page-link.
Function Blocks Enable
savvyPanel
Actions
Enumerated Parameter
block in
Utility
group. Only custom
enumerations appear in the setter and multi-position switch.
In the
savvyPanel
function block group:
Latch
and
SR Latch
support
lighted start-stop pushbuttons.
Setpoint & Monitor
blocks control meter range.
Setpoint
clamps setter. Dual blocks enable dual display meters
savvyPanel
Launch, Setup and Important Notes
See the
savvy
User manual for detailed instructions.
Launch
savvyPanel
from a command line or batch file.
Limit operators to
savvyPanel
-only, specify start system & page.
Discover devices specifically by discovery file, automatically or
filtered by group and/or
savvyPanel
name.
Operator’s Note: If communication with a
drive.web
device is
interrupted, affected tiles indicate a yellow bar at top with an
exclamation warning. The displayed value is not updated.
Important Design Note: An over-range enumeration is required if
misreading an out-of-range value could cause a hazard.