background image

EMC  Standard,  EN  61326-1:  2006,  Electrical  Equipment  for  Measurement,  Control  and 

Laboratory Use.

 

Emissions Class A, Commercial Equipment.

 

Immunity Table 2, Industrial Equipment.

LVD  Standards,  EN  61010-1:  2010,  Safety  Requirements  for  Electrical  Equipment  for 

Measurement, Control and Laboratory Use and; 

 

EN 61010-2-030: Particular Requirements for Testing and Measuring Circuits.

speedy

  is  an  industrial controller  designed  for permanent  installation  by qualified  professionals. 

If  it is used in a manner not specified herein the protection provided may be impaired.

speedy 

and its packaging contain recyclable materials.

This  device  is  designed  to  comply  with  Part 15  of  FCC Rules.  Operation  is subject to the following 

two  conditions:  (1)This  device  may  not  cause  harmful  interference,  and  (2)this  device must 
accept any interference received, including interference that may cause undesired operation.

This  Class  [A]  digital  apparatus  is  designed  to  comply  with  Canadian  ICES-003.    Cet  appareil 

numerique de la classe [A] est conçu conformer à la norme NMB-003 du Canada.

Warning! 

It  is  essential  that  you  read  and  understand  this  entire  manual  and  the  entire 

contents  of  the 

savvy

  software 

Help

  menu  before  proceeding  with  your  installation  and 

configuration.  See  page  9  for 

savvy 

installation  instructions.  For  more  information  and  to 

download manuals and software, go to

 www.driveweb.com

 or contact us. See page 24.

Warning! 

Your  use  of 

savvy

 

software  and 

drive.web

 

devices  may  cause  motors  and 

machinery to power  up  with  high Voltages  or  start or  operate in  an  unexpected,  dangerous or lethal 
way.  It is  essential  that you are completely  familiar  with  all of  the equipment and  the system  design 
before attempting to program or edit a  program  or  connect to  any live device.  It is also  essential  that 
a risk assessment is conducted to identify hazards. Risks must be reduced to tolerable levels.

Warning! 

You  are entirely responsible  for  the configuration  or  use of  any 

drive.web

 

product. 

By  configuring  or  using  these  products  you  agree  to  indemnify  and  hold  harmless  Bardac 
Corporation,  its’  employees,  directors,  officers,  distributors and  resellers against the  consequences  of 
your configuration or use of  the products.

Warning! 

Information  in  this  manual  is subject to  change without  notice.  You  are responsible 

for  verifying the proper operation  of  your 

speedy

 module.  Special  care must be taken after loading 

new firmware or installing new options.

Warning! 

Avoid  permanent  damage to  your 

speedy

,  never  exceed  any 

min

 or 

max

  values.  

Do not connect any 

speedy

 terminal to mains circuits. See page 8 for IO ratings.

drive.web automation

speedy

 

HG503206beta2

 

www.driveweb.com

 

           

Page 2/20

This product is designed to conform to CE and UL standards:

lwIP is incorporated into 

speedy

 firmware. lwIP Copyright (c) 2001-2004 Swedish Institute of  Computer Science. All rights reserved.

Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:
1. Redistributions of  source code must retain the above copyright notice, this list of  conditions and the following disclaimer.
2.  Redistributions  in  binary  form  must  reproduce  the  above  copyright  notice,  this  list  of  conditions  and  the  following  disclaimer  in  the 
documentation and/or other materials provided with the distribution.
3. The name of  the author may not be used to endorse or promote products derived from this software without specific prior written permission.
THIS  SOFTWARE  IS  PROVIDED  BY  THE  AUTHOR  ``AS  IS''  AND  ANY  EXPRESS  OR  IMPLIED  WARRANTIES,  INCLUDING, 
BUT  NOT  LIMITED  TO,  THE  IMPLIED  WARRANTIES  OF  MERCHANTABILITY  AND  FITNESS  FOR  A  PARTICULAR 
PURPOSE ARE DISCLAIMED.  IN  NO EVENT  SHALL THE AUTHOR  BE  LIABLE FOR  ANY DIRECT,  INDIRECT,  INCIDENTAL, 
SPECIAL,  EXEMPLARY,  OR  CONSEQUENTIAL  DAMAGES  (INCLUDING,  BUT  NOT  LIMITED  TO,  PROCUREMENT  OF 
SUBSTITUTE  GOODS  OR  SERVICES;  LOSS  OF  USE,  DATA,  OR  PROFITS;  OR  BUSINESS  INTERRUPTION)  HOWEVER 
CAUSED  AND  ON  ANY  THEORY  OF  LIABILITY,  WHETHER  IN  CONTRACT,  STRICT  LIABILITY,  OR  TORT  (INCLUDING 
NEGLIGENCE OR OTHERWISE) ARISING  IN  ANY WAY OUT  OF THE  USE  OF  THIS  SOFTWARE,  EVEN  IF  ADVISED  OF  THE 
POSSIBILITY OF SUCH DAMAGE.

Содержание dw220

Страница 1: ...rator station 13 14 speedy Comms Interfaces Modbus and EIP PCCC 15 17 Option 06 winder control library 17 savvy savvyPanel diagrammatic overview 18 19 drive web product line highlights 20 Free drive w...

Страница 2: ...nfiguring or using these products you agree to indemnify and hold harmless Bardac Corporation its employees directors officers distributors and resellers against the consequences of your configuration...

Страница 3: ...irmware Ultra compact design may be permanently bonded inside equipment High speed ModbusRTU on EIA485 Up to 500kb s Drive dedicated models can bus share EIA485 network to control or monitor additiona...

Страница 4: ...Voltages that may cause injury or death are present on drives motor controllers and other industrial devices Only qualified personnel who are completely familiar with the system that the speedy will...

Страница 5: ...permanent Adhere on or near the drive or EIA485 device Do not obstruct air vents access points or product labels Do not attach speedy near hot spots such as heatsinks cooling fans etc nor near to AC p...

Страница 6: ...andard 15 24AWG solid wire connections with DIN rail mount option Single local device connections 24V 0V C A B 0V 24V C A B 24V 0V A B 24V 0V C A B YF7 terminal Wire name SP 24V IG and SN 0V C S and R...

Страница 7: ...orks with line polarization 120 0 25W and 1nF 10V cap in series Do NOT provide line termination on any network with an Optidrive Drive setup speedy model Supported drive Required drive settings Relate...

Страница 8: ...istration section Set up Your Physical Ethernet Network You Will Need A standard Category 5e cable with 8P8C RJ 45 connectors on both ends for each drive web device and your computer For systems with...

Страница 9: ...Use the navigation arrows to view the next higher level or go backward and forward through views Note that window menus change as you navigate Hover mouse cursor over any active object device functio...

Страница 10: ...f the Set IP Addresses window click the arrow next to Network Information to set subnet mask router SMTP mail server and SNTP time server IP addresses See the savvy user manual Note If the Network Inf...

Страница 11: ...g a connection will result in immediate execution of that connection Dangerous Voltages and rotating machinery may result Connect between parameters and to parameters in other drive web devices over E...

Страница 12: ...on Click Apply savvy SFD Signal Flow Diagram Upgrade With savvy SFD build systems graphically while creating live drawings that are stored in your speedy Set borders with user attributes drag and drop...

Страница 13: ...Temp or Set Tension to open the setter and make changes Touch the parameter name in the setter to get info Touch page link arrows to browse demo pages Drive the demo with savvy in your computer In the...

Страница 14: ...ion block group Latch and SR Latch support lighted start stop pushbuttons Setpoint Monitor blocks control meter range Setpoint clamps setter Dual blocks enable dual display meters savvyPanel Launch Se...

Страница 15: ...FBE or SFD view to configure Comms Server Indirect parameters are sequentially numbered Enter any parameter numbers to read or write them all with one operation Add more with Comms Server Indirect fu...

Страница 16: ...speedy s dw220 choose standard speeds are enter baud rate 0 1 to 500Kbps Comms Configuration Read only in dedicated speedy s Character frame is 1 8 Parity Stop Parity is N None O Odd E Even S Space 0...

Страница 17: ...ported by your server Priority Three levels Round robin scheduler processes all High priority data blocks plus one other every round All Medium priority blocks are processed one per round then first L...

Страница 18: ...ce function blocks graphically use function block list to review and arrange execution order Function Block View functional elements and signal paths in relation to parameters Parameters show type dri...

Страница 19: ...any operator page by pressing the home button Graphic tiles can be page links Up to 256 possible May be page linked in any way Set savvy preferences so that operators view a specific page at launch Us...

Страница 20: ...station app see pages 14 to 17 All drive web products are designed assembled in the U S A Get expert drive web help Call or email techsupport driveweb com drive web training courses Free online intera...