07-01776H F412-115V
3
Dri-Eaz Products, Inc.
Set up drain hose
The condensate pump connects to a plastic drainage
hose that is located in the pocket on the side of the unit.
This hose is equipped with a quick-connect fitting for
quick attachment to the provided 40 ft. (12 m) drain
hose. Unwrap the entire hose and place the unattached
end in a sink, drain, bucket or outdoors
– anywhere that
water can drain out safely. If you use a bucket or other
container for water collection, check it regularly to
prevent overflows.
NOTICE:
Uncoil and straighten the entire drain hose. Do
not leave any part of the hose coiled on the unit and do
not place the end of the hose higher than 20 ft. (6 m)
above the bottom of the unit. Also check for kinks or
other obstructions that might restrict the flow of water.
Obstructions may cause a water backup and result in
overflows.
Plug in electrical cord
The dehumidifier should be plugged into a
GFCI-
protected 115 volt outlet rated for at least 15
amps.
Remove the cord from its storage pocket and uncoil it.
Always plug the cord firmly into the unit first, and then
plug the other end into a suitable outlet.
Turn the unit on
The control panel has a display and a touchpad with four
keys. Press the
ON/OFF
to turn the unit on.
Startup display and normal display modes
When unit is first plugged in to AC power, the control
panel display will briefly cycle through a series of
rea
douts. This is part of the unit’s self-diagnosis
procedure and no user intervention is required.
Once the self-diagnosis is complete, the display will
switch to
normal display mode
.
UNIT ON 00 HRS
INLET 00°C / INLET 00%
The
first line
of the display shows the total number of
hours the unit has been in operation. This value may be
reset to zero to track job hours (see “Job Hours Reset”
below). The
second line
of the display alternates
between inlet temperature and inlet humidity.
User Settings Menu
A number of settings may be changed by the user.
System information can also be displayed. These items
are accessed by pressing
DISPLAY MENU. Each
press of the key will display the next parameter. When
you reach the parameter you wish to adjust, press
MENU SELECTION to increase the value. Press
DISPLAY MENU again to accept the setting and re-start
the display cycle.
Note that only menu items followed by a greater-than
symbol (
>
) may be adjusted.
Error messages
If the onboard diagnostics discover a problem, the unit
will display an error message. See “Error Messages,” p.
10, for an explanation of each message.
Control Panel Guide
ON/OFF
.
Press to turn the unit on or off. When the
machine is turned on, the display normally reads
PLEASE WAIT COMP. DELAY and performs a numeral
countdown from a maximum of 60 seconds to 0. This
delay allows time for refrigerant pressures to equalize for
easier starting. Once the unit completes the compressor
delay, the display shows UNIT ON XX HRS and cycles
between INLET XX°F and INLET XX%. NOTE: If no
compressor delay countdown is displayed, a delay is not
necessary and the machine will begin operation
immediately.
DISPLAY MENU.
Press to cycle through the display
of additional dehumidifier conditions and User Settings.
To return to the main menu, press the ON/OFF key
once.
MENU SELECTION.
Press to change the values of
the "User Defined" settings. The MENU SELECTION
key acts as the UP key for adjusting the setpoint for
Humidistat mode operation. See User Settings Menu
(next page) for details.
PURGE.
Press to empty water from the condensate
pump reservoir. The display will read PUMP PURGING
ON/OFF
Press and release to turn unit on
or off.
DISPLAY MENU
Press to select next item in menu.
Menu item will show in display.
MENU SELECTION /
UP KEY
Press to toggle or select values in
menu displayed.
PURGE PUMP
Press and release to start purge.
Display will count down seconds
remaining until purge is complete.
CONTROL PANEL
ON/OFF
DISPLAY
DISPLAY
MENU
MENU
SELECTION /
UP KEY
PURGE PUMP