4-50
Communication Interfaces
HPG 13150 400 V (A)
Dressler
®
HF-Technik GmbH
Prerelease version
29
set remote
control
override
Sets
Remote Control Override
, which
enables partial front panel control (see
also
Send one data byte:
• Bit 0 = RF On/Off buttons enabled
• Bit 1 = Rotating Knob enabled
• Bit 2 = Matching buttons enabled as
follows:
4
0 = Buttons and knob disabled
4
1 = RF On/Off buttons enabled
Rotating knob disabled
Matching buttons disabled
4
2 = RF On/Off buttons disabled
Rotating knob enabled
Matching buttons disabled
4
3 = RF On/Off buttons enabled
Rotating knob enabled
Matching buttons disabled
4
4 = RF On/Off buttons disabled
Rotating knob disabled
Matching buttons enabled
4
5 = RF On/Off buttons enabled
Rotating knob disabled
Matching buttons enabled
4
6 = RF On/Off buttons disabled
Rotating knob enabled
Matching buttons enabled
4
7 = RF On/Off buttons enabled
Rotating knob enabled
Matching buttons enabled
1
1
(CSR only)
Table 4-13. Host port commands (Continued)
Command
Description
Number of
Host Data
Bytes
Number of
Response
Data Bytes
Содержание 13150 400 V
Страница 2: ......
Страница 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Страница 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Страница 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Страница 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Страница 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...