HPG 13150 400 V (A)
Communication Interfaces
4-11
HPG™ 13150 400 V RF Power Generator
Prerelease version
8
21
RF FORWARD/
LOAD POWER
REGULATION
Digital
input
Use this signal to select
between RF forward power or
load power regulation. Apply
a positive DC input voltage of
4 V to 30 V to regulate on
load power. An open
connection to pin
8
or a DC
input voltage of less than
1.5 V causes forward power
regulation.
Load power is defined as
forward power minus
reflected power.
Note:
Pin 6 also changes the
regulation mode.
For a wiring diagram, see
.
9
Return for pin
22
See pin 22.
10
23
INTERLOCK
LOOP
Digital
input
To satisfy the interlock and
enable RF power in the
generator, close an external
loop from pin 23 to pin 10. A
resistance of 15
Ω
or less
across this pin closes the
loop. Pin 23 feeds this loop
via a current limiting circuit
(maximum 120 mA).
Alternatively, you can satisfy
the interlock by applying a
voltage of +4 V to +30 V
(referenced to ground) to pin
10.
For a wiring diagram, see
.
11
Return for pin
24
See pin 24.
12
Reserved
Table 4-2. 25-pin User Port pin descriptions (Continued)
Pin
Number
Return
Pin
Name
Signal
Type
Description
Содержание 13150 400 V
Страница 2: ......
Страница 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Страница 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Страница 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Страница 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Страница 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...