HPG 13150 400 V (A)
Installation, Setup, and Operation
5-15
HPG™ 13150 400 V RF Power Generator
Prerelease version
To Select External Power Regulation Through the User Port:
See pin 8 on the 25-pin
User port
“RF forward/load power regulation” on
.
To Select External Power Regulation Through the Host Port:
If you are using
RS-232
,
PROFIBUS
, or
Ethernet
to control and monitor the
HPG generator:
1. Select external power regulation:
Send one data byte for command
3
(see
).
4
8 = External power regulation (DC Bias)
2. Specify the maximum forward power that can be delivered:
Send two data bytes, least significant byte first, for command 4
representing the maximum forward power in watts (see
).
3. Specify the output set point level for the regulation mode:
Send two data bytes, least significant byte first, for command
8
representing the set point level in watts (see
Selecting DC Bias Regulation Using the HPG Generator Front Panel:
Complete the following steps to select DC Bias regulation mode using the
front panel:
1. Press the
Program
soft key.
Control Settings
appears on the display.
2. Press
Change
.
3. Press
Control DC Bias
.
4. Set a DC Bias value using the
RF POWER
dial knob. Press the
Increm
Auto
soft key to toggle between dynamic increments (Auto) and several
fixed increments.
4
The value can be between 0 V and 4000 V
Note:
4000 V is the default value. To change the default settings, see
5. Press
Ok
to confirm.
6. Set a P
forward
maximum value between 5% of nominal power and 15 kW
into a 50
Ω
nonreactive load using a combination of the
Increm Auto
and
the
RF POWER
dial knob.
7. Press
Ok
to confirm.
8. Press
Exit
.
9. Press
Execute
.
Содержание 13150 400 V
Страница 2: ......
Страница 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Страница 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Страница 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Страница 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Страница 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...