HPG 13150 400 V (A)
Installation, Setup, and Operation
5-27
HPG™ 13150 400 V RF Power Generator
Prerelease version
3. Press
Change
.
4. Press
Power Ramping
.
a. Select the number of time frames (1 to 4) you want to use in your recipe
using the
RF POWER
rotary knob.
b. Press
Ok
to confirm.
c. Set a time for T1 (the recipe’s first power ramp) between 0.1 s and 60
minutes using a combination of the
Increm Auto
key and the
RF
POWER
rotary knob.
d. Press
Ok
to confirm.
e. Set a
Start Power
value for T1 between 0 W and 15 kW into a 50
Ω
nonreactive load using a combination of the
Increm Auto
key and the
RF POWER
rotary knob.
f. Set a
Final Power
value for T1 between 0 W and 15 kW into a 50
Ω
nonreactive load using a combination of the
Increm Auto
key and the
RF POWER
rotary knob.
g. Press
Ok
to confirm.
h. Set a time for T2 (the recipe’s second power ramp) between 0.1 and 60
minutes using a combination of the
Increm Auto
key and the
RF
POWER
rotary knob.
i. Press Ok to confirm.
j. The
Start Power
value will display as the final value of T1; set a
Final
Value
for T2 between 0 W and 15 kW into a 50
Ω
nonreactive load using
a combination of the
Increm Auto
key and the
RF POWER
rotary knob.
k. Repeat the last three steps to set time frames for T3 and T4 (the
recipe’s third and fourth power ramps).
5. Press
Ok
to confirm.
6. Press the
Exit
soft key.
7. Press the
Execute
soft key.
The operating screen will change to display the current recipe status. See the
following illustration for an example.
Содержание 13150 400 V
Страница 2: ......
Страница 3: ...User Manual Prerelease version HPG Generator Model 13150 400 V HPG 13150 400 V A ...
Страница 6: ...iv HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Страница 12: ...x List of Figures HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Страница 14: ...xii List of Tables HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...
Страница 104: ...4 66 Communication Interfaces HPG 13150 400 V A Dressler HF Technik GmbH Prerelease version ...