- 9 -
Mount the water heater in vertical position.
The fixing wood screws must have guaranteed
spacing t=180 mm and spacing F according to the heater volume
or with hinges.
2 upper hinges are attached to the wall and 2 lower hinges are fitted into the bottom holes on
the heater, the lower hinges serve as abutment (
).
Hinges (4 pcs) are included in
package.
Figure 3
Figure 4
The ONE heater can also be installed in a horizontal position.
Considering the laws of physics,
its energetic performance drop will always occur due to deteriorated stratification of water.
However, neither lifecycle nor terms of warranty are changed thereby. Our heaters are tested
for operation in the horizontal position. In use in the horizontal position it is recommended that
the user set a temperature higher on the thermostat than factory optimum value.
Recommended value is 65
°C.
Direction of placement - to the left due to the fact the heating flange must be placed in a lowered
reservoir.
When installing in a horizontal position, only two bolts may be used for hanging (upper holes).
F
OKHE ONE/E 30
350
OKHE ONE/E 50
560
OKHE ONE/E 80
750
OKHE ONE/E 100
950
OKHE ONE/E 120
1150