- 15 -

 

 

Attention!

 In doing so, the cold water supply pipe and the connection fitting of the tank may get 

heated! If the hot water heater does not work, or if hot water is not withdrawn, no water shall 
drip off the safety valve. If water drips, then the water pressure in the supply piping is either too 
high (if higher than  4.8  bars, a pressure  control valve  has to  be  fitted), or the safety valve  is 
defective. Please call a specialized plumber immediately! 

If water contains too many minerals, an expert has to come to remove the scale that forms inside 
the tank, as well as free sediments. This has to be performed after one or two years of operation. 
The cleaning is carried out through the hole in the flange - dismantle the flange lid and clean the 
tank. A new sealing has to be used for re-fitting. Since the inside of the heater has special enamel, 
which must not get in contact with the scale removing agent - do not work with a lime pump. 
Remove the lime layer with a timber and suck it off, or wipe it off with a clout. After that, the 
appliance must be rinsed thoroughly, and the heating process is checked the same as during the 
initial  putting  in  operation.  Do  not  use  any  abrasive  cleaning  agents  (such  as  liquid  sand, 
chemicals - acid, alkaline) or dye thinners (such as cellulose thinner, trichlor, and the like)to clean 
the outer shell of the heater. For cleaning use a wet clout and add a few drops of liquid cleaning 
agent for household applications. Repeated heating causes lime scale settling on the receptacle 
walls and mostly on the lid of the  flange.  Lime scale settling depends on hardness of heated 
water, its temperature and on the volume of hot water used. 

We recommend checking and cleaning the tank from scale and eventual replacement of the 
anode rod after two years of operation.

 The anode life is theoretically calculated for two years 

of operation; however, it changes with water hardness and chemical composition in the place 
of use. Based on such an inspection, the next term of anode rod exchange may be determined. 
If the anode is only blocked with sediments clean its surface and, if used up, mount a new one. 
Have a company in charge of service affairs deal with the cleaning and exchanging of the anode. 
When draining water from the heater, the combination faucet valve for hot water must be open, 
preventing occurrence of under-pressure in the heater tank which would stop the water from 
draining. 

 

 

Содержание OKHE ONE/E 120

Страница 1: ...ER FOR VERTICAL MOUNTING Electric water heaters OKHE ONE E 30 OKHE ONE E 50 OKHE ONE E 80 OKHE ONE E100 OKHE ONE E 120 Dru stevn z vody Dra ice stroj rna s r o Dra ice 69 294 71 Ben tky nad Jizerou te...

Страница 2: ...INSTALLATION 12 2 4 1 GENERAL INFORMATION FOR ELECTRICAL INSTALLATION 12 2 5 OPERATING ACTIVITY 13 2 6 FIRST COMMISSIONING 13 2 7 PUTTING OUT OF SERVICE DISCHARGE 14 2 8 INSPECTION MAINTENANCE CARE F...

Страница 3: ...le person or unless properly instructed by such responsible person The manufacturer reserves the right for engineering modification of the product The product is designed for permanent contact with dr...

Страница 4: ...MERS 1 2 1 HOT WATER CONSUMPTION Consumption of hot water in households depends on the number of people amount of sanitary equipment length diameter and insulation of piping in the flat or on individu...

Страница 5: ...ERATURE OF HOT WATER HW C 80 RECOMMENDED HOT WATER HW TEMPERATURE C 60 HEIGHT OF THE HEATER mm 617 845 1112 1327 1552 HEATER DIMENSION width x depth mm 523x318 MAX WEIGHT OF THE HEATER WITHOUT WATER k...

Страница 6: ...e flange lid and the safety fuses and the second flange lids are without thermowells An anode rod is mounted onto the M8 nut Electric wiring is placed underneath the plastic removable cover Descriptio...

Страница 7: ...E ONE E 30 OKHE ONE E 50 OKHE ONE E 80 OKHE ONE E 100 OKHE ONE E 120 A 617 845 1112 1327 1552 B 318 318 318 318 318 D 523 523 523 523 523 E 500 730 920 1135 1360 F 350 560 750 950 1150 H 110 110 190 1...

Страница 8: ...2 2 WALL MOUNTING Prior to the mounting check the bearing capacity of the wall and the material it is made of considering the weight of the heater filled with water Depending on the wall material choo...

Страница 9: ...energetic performance drop will always occur due to deteriorated stratification of water However neither lifecycle nor terms of warranty are changed thereby Our heaters are tested for operation in th...

Страница 10: ...peration of the check valve with a check valve and a relief valve Figure 6 The safety valve with a check valve is supplied with the heater It is necessary to check the safety valve each time before pu...

Страница 11: ...11 Table 3 Figure 6 Figure 7 SAFETY VALVE START UP PRESSURE MPa ALLOWABLE OPERATING OVERPRESSURE OF WATER HEATER MPa MAXIMUM PRESSURE IN COLD WATER PIPES MPa 0 6 0 6 up to 0 48...

Страница 12: ...ure 8 The electric installation may only be connected repaired and inspected only by a person authorized to perform that activity Professional connection must be confirmed on the warranty card or supp...

Страница 13: ...lake symbol to avoid freezing or turn off the power supply into the heater Setting the thermostat to the zero position does not mean the heater has been turned off In case of a power failure the displ...

Страница 14: ...supply piping through the discharge valve for safety valve combination and with simultaneous opening of all hot water valves of connected fittings water can be also drained through safety valve for t...

Страница 15: ...same as during the initial putting in operation Do not use any abrasive cleaning agents such as liquid sand chemicals acid alkaline or dye thinners such as cellulose thinner trichlor and the like to...

Страница 16: ...ration thermostat Water is not warm enough Light on Failure of one of the coils in the element 2x 1000 W Temperature of water is not corresponding with the temperature set on the control Defective the...

Страница 17: ...e used for any handling with the heater 3 1 1 TEMPERATURE SETTING Water temperature is set by turning the thermostat knob The desired symbol is adjusted against the fixed point on the control panel Fi...

Страница 18: ...ing adjustment and replacement of the regulation elements shall only be performed by an authorized service company The thermal fuse must not be turned off In case of thermostat defect the thermal fuse...

Страница 19: ...is F06020274 Take the water heater packaging to a waste disposal place determined by the municipality When the operation terminates disassemble and transport the discarded and unserviceable heater to...

Отзывы: