2.4
ELECTRICAL INSTALLATION
2.4.1
GENERAL INFORMATION FOR ELECTRICAL INSTALLATION
Perform the connection according to the scheme. Factory connection must not be changed! (Figure 8).
The degree of protection of electric parts of the heater is IP 44. The power input of electric element is 2.000 W
(OKHE ONE/E 50 - 120), 1.100 W (OKHE ONE/E 30).
Figure 8
It is necessary to observe the below requirements during the electric wiring.
•
The wiring diagram is attached to the heater on the side of the electric installation cover
(Figure 8).
•
The electric installation may only be connected, repaired and inspected only by a person
authorized to perform that activity.
•
Professional connection must be confirmed on the warranty card, or supported by
another document.
•
The heater is connected to 230V/50Hz power supply by a fixed movable cable (depending
on the connection method).
•
When installing in bathrooms, laundry rooms, rest rooms and showers, it is necessary
to follow the relevant standard.
•
The degree of protection of electric parts of the heater is IP 44.
•
Adhere to the protection against electric shock according to the standard
If the supply cord is damaged, it must be replaced by a company (person) authorized to such
activity in order to avoid a hazard.